IntelliTouch
®
Control System User’s Guide
81
iS10 circuit/button setup
Configuring Remote Control Button Circuits
(iS4, iS10, SpaCommand Spa Side Remote, Quick-
Touch (QT4) and phone remote)
From the spa side remote screen you can configure the iS4, iS10 and
SpaCommand
®
buttons to control different pool/spa functions, including
IntelliFlo VF 3050, VS 3050 and VSF+SVRS pump speeds. Up to two iS4
remotes, and four iS10 and SpaCommand remotes can be connected to an
IntelliTouch system. To assign a circuits to spa-side remote buttons:
1. Press the button next to
CONFIGURE iS4’S
or
CONFIGURE 10 BUTTON SS’s
or
CONFIGURE QUICKTOUCH
to select the remote.
• For iS4:
Press the top button to access the setup screen for
iS4 #1
and
iS4 #2
. See note below if multiple iS4 remotes are installed.
• For iS10 and SpaCommand:
Press top button to select
10
BUTTON SPA SIDE #1
for the first iS10 or SpaCommand remote.
Choose which one of the four remotes you are configuring,
10
BUTTON SPA SIDE #1 #2, #3 or #4
. See note below if multiple
iS10 or SpaCommand remotes are installed.
• For QuickTouch:
Press the button next “CONFIGURE QUICKTOUCH”
to access the setup screen.
2.
On the next screen:
Press the button next to the circuit you wish
to assign. A small arrow is displayed pointing to the name of that
circuit. Use the
Up
and
Down
buttons at the bottom of the screen
to scroll through the iS10 or iS4 circuit names (SPA, POOL, AUX
1-8, HEAT BOOST, HEAT ENABLE,
INCREASE PMP SPD
,
DECREASE PMP SPD
, NONE).
For QuickTouch:
(SPA, POOL,
AUX 1-4, POOL).
Note: When assigning buttons to “Increase” and
“Decrease” the IntelliFlo VF (GPM), VS (RPM) and VSF+SVRS
(RPM/GPM). Each press of the assigned button increases or
decreases the pump’s “step” flow rate or speed until the GPM or
RPM is reached as specified in the “SPA SIDE INFLO CONTROL” screen
(on the 10 Button SS screen). Be sure to set the
pump address number (in the IntelliFlo screen) for the pump you
wish to control.
iS4 circuit/button setup
DEC PMP SPD
INC PMP SPD
iS4 spa side remote
LED
Note: For systems with four iS10/SpaCommand remotes, adding one or two
iS4 remotes will affect button function assignments as follows: Assigned button
functions 1 - 4 on iS4 #1 are linked with the same functions to buttons 1 - 4 (top row) of
iS10 #4. Also, buttons 1 - 4 on iS4 #2 are linked to buttons 6 - 10 (bottom row) of iS10
#4. For example, button 6 on the bottom row of iS10 #4 is linked to button 1 of iS4 #2,
button 7 on iS10 #4 is linked to button 2 of iS4 #2, etc.
INTELLIFLO PUMP # 1
STEP SIZE 10 GPM
SPA SIDE IFLO CONTROL
screen
Содержание INTELLITOUCH
Страница 9: ...vii IntelliTouch Control System User s Guide BlankPage...
Страница 99: ...IntelliTouch Control System User s Guide 89 WORKSHEET FOR SHARED EQUIPMENT SYSTEMS i5 3 i7 3 i9 3 Sheet 1 of 2...
Страница 100: ...IntelliTouch Control System User s Guide 90 WORKSHEET FOR SHARED EQUIPMENT SYSTEMS i5 3 i7 3 i9 3 Sheet 2 of 2...
Страница 101: ...IntelliTouch Control System User s Guide 91 WORKSHEET FOR SINGLE BODY SYSTEMS i5S 3 i9 3S Sheet 1 of 2...
Страница 102: ...IntelliTouch Control System User s Guide 92 WORKSHEET FOR SINGLE BODY SYSTEMS i5S 3 i9 3S Sheet 2 of 2...
Страница 103: ...IntelliTouch Control System User s Guide 93 WORKSHEET FOR DUAL EQUIPMENT SYSTEMS i10 3D Sheet 1 of 2...
Страница 104: ...IntelliTouch Control System User s Guide 94 WORKSHEET FOR DUAL EQUIPMENT SYSTEMS i10 3D Sheet 2 of 2...
Страница 121: ...IntelliTouch Control System User s Guide 111 IntelliTouch Control System Wiring Diagram i10 3D i5 3S i9 3S and i10 3D...
Страница 126: ...NOTES...
Страница 127: ...NOTES SAVE THESE INSTRUCTIONS...