IntelliTouch
®
Control System User’s Guide
39
Assign Circuit Functions and Freeze Protection
Assigning a function to an auxiliary circuit allows certain type of equipment to operate in a
specific way. For example, when setting up an automatic pool cleaner pump, you would assign the
circuit function to MASTER CLEANER. With this “Cleaner” logic, when the circuit is switched
on the cleaner pump would force the filter pump on, and start the cleaner pump after a delay of
five (5) minutes. The cleaner pump would automatically shut off whenever the spa and solar is
switched on with the cleaner pump (after a delay of five (5) minutes) if energy from the solar is
required.
Freeze Protection
Freeze protection switches a circuit on if the outdoor air temperature sensor detects the
temperature is getting close to freezing (below 36° F (2 ° C). The system switches on all circuits
that have been assigned freeze protection, and switches on the filter pump to circulate water
throughout the system for 15 minutes to stop the pipes from freezing. This is especially important
for a pool and spa combination (dual body shared equipment). If freeze protection is set to both
the spa and pool circuits, the filter pump switches on and the pool and spa valves alternate every
15 minutes to keep the water moving through both the pool and spa. This process continues until
the freeze condition is over.
Assigning a function and freeze protection to a circuit
To assign a function to an auxiliary circuit and to add circuit freeze
protection:
1. Press the button next to the circuit name that requires a
function.
2. Press the lower DISPLAY button to view the Feature circuits.
Select the Feature circuit name to assign a function to it. Use
this button to toggle between the Feature circuit screen and the
Circuit screen.
MENU SETUP
ADVANCED CIRCUIT FUNCTIONS
SELECT DESIRED CIRCUIT
SELECT DESIRED SCREEN
DISPLAY 1,2,3,4 or F
This Button appears only
when you have FEATURE
circuits or multiple DISPLAYS.
Getting There
AUX 2
AUX 4
AUX 7
AUX 6
AUX 5
AUX 8
BACK
DISPLAY
EXIT
FLOOR CLNR
FOUNTAIN
MENU/SETUP/ADV/FUNCTION/SELECT
1
MENU
HEAT
LIGHTS
DISPLAY
EDGE PUMP
CLEANERS
F
MON 4:32AM
AIR TEMP 92˚
ALL LIGHTS
WATER FALL
CLEANERS
Содержание INTELLITOUCH
Страница 9: ...vii IntelliTouch Control System User s Guide BlankPage...
Страница 99: ...IntelliTouch Control System User s Guide 89 WORKSHEET FOR SHARED EQUIPMENT SYSTEMS i5 3 i7 3 i9 3 Sheet 1 of 2...
Страница 100: ...IntelliTouch Control System User s Guide 90 WORKSHEET FOR SHARED EQUIPMENT SYSTEMS i5 3 i7 3 i9 3 Sheet 2 of 2...
Страница 101: ...IntelliTouch Control System User s Guide 91 WORKSHEET FOR SINGLE BODY SYSTEMS i5S 3 i9 3S Sheet 1 of 2...
Страница 102: ...IntelliTouch Control System User s Guide 92 WORKSHEET FOR SINGLE BODY SYSTEMS i5S 3 i9 3S Sheet 2 of 2...
Страница 103: ...IntelliTouch Control System User s Guide 93 WORKSHEET FOR DUAL EQUIPMENT SYSTEMS i10 3D Sheet 1 of 2...
Страница 104: ...IntelliTouch Control System User s Guide 94 WORKSHEET FOR DUAL EQUIPMENT SYSTEMS i10 3D Sheet 2 of 2...
Страница 121: ...IntelliTouch Control System User s Guide 111 IntelliTouch Control System Wiring Diagram i10 3D i5 3S i9 3S and i10 3D...
Страница 126: ...NOTES...
Страница 127: ...NOTES SAVE THESE INSTRUCTIONS...