Minimum combustion power
8,500 Btu / hour = 1 lb/h - 2.5 KW / h = .45 kg/h
Maximum combustion power
34,000 Btu / hour = 4 lb/h - 10 KW / h = 1.81 kg/h
Combustion efficiency
86% net efficiency
Power of the combustion fan
25 to 45 cubic feet/min - .7 to 1.3 meter cube / min
Power of the convection fan
25 to 45 cubic feet/min - 1 to 3.5 meter cube / min
Hopper capacity
55 lbs - 24.9 kg
Certification
EN 14785, UL, ULC-C1482, EPA, ASTM E1509,
84-HUD
Emission of particles in the atmosphere
0.6 g/h
Power settings
5 levels
AC voltage required
120 to 240 volts / 50 or 60 hertz
Power consumption on 120 volts AC
Min .25 amps / Max .65 amps
Power consumption on 240 volts AC (Europe)
Min .15 amps / Max .35 amps
Power consumption on 12 volts DC
Min 1.8 amps / Max 4.5 amps (12.8V)
Standby power consumption on 120 volts AC
240 volts AC
0.10 amps
0.07 amps
Standby power consumption on 12 volts DC
0.32 amps at 12.8 volts
Height
34 3/4” - 88.2 cm
Width
22 3/8” - 56.8 cm
Depth
23 1/4” - 59 cm
Weight
285 lbs - 129 kg
Type of chimney for wood pellets
Double wall PL version
Type of chimney for corn or wheat
Double wall PL stainless steel version
Inside diameter of the chimney
3” - 7.6 cm
Patent
US 6,336,449