NOTES :
1. Do not terminate the vent in any enclosed or semi-enclosed areas that can build up a
concentration of smoke.
2. Vent surfaces can become extremely hot. Keep children away from such areas. Non-combustible
shielding or guards may be required.
3. Termination must exhaust above sea level and the inlet elevation. It is recommended to have a
short vertical run which will help in the event of total power failure.
4. If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of
the exterior of the house might occur. Since these factors are beyond our control we offer no
guarantee against such incidents.
5. When installing into an existing masonry chimney, you will probably need a short horizontal
section to clear the lintel and allow the hopper lid to open.
6. Vent terminations shall not be recessed into walls or siding.
7. A vent shall not terminate directly above a sidewalk or paved driveway which is located between
two single family dwellings and serves both dwellings.
8. If the vent termination is children accessible, a certified guard shall be installed as specified in
CGA B149 installation Code in Canada. Note: Local codes or regulations may require different
clearances.
Minimum
Description
A
24” / 61 cm
Above lawns, top of plants, wood or any other combustible materials.
A
12” / 30.5 cm
Above non-combustible surface such as cement and gravel.
B
48” / 122 cm
From beside/below any door or window that may be opened.
C
12” / 30.5 cm
From above any door or window that may be opened.
D
24” / 61 cm
To any adjacent building, fences and protruding parts of the structure.
E
24” / 61 cm
Below any eaves or roof overhang.
F
12” / 30.5 cm
To outside corner.
G
12” / 30.5 cm
To inside corner, combustible wall (vertical & horizontal terminations).
H
36” / 91.5 cm
To each side of center line extended above natural gas or propane meter/
regulator assembly or mechanical vent within a height of 15’ / 4.5 m above
the meter/regulator assembly.
I
36” / 91.5 cm
From any forced air intake of other appliance.
J
12” / 30.5 cm
Clearance to non-mechanical air supply inlet to building or combustion air
inlet to any appliance.
K
24” / 61cm
Clearance above roof line for vertical terminations.
IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED
BY A PAROMAX AUTHORIZED DEALER/INSTALLER.
10
Installation
CLEARANCE TABLE
: Use in conjunction with diagram below for allowable exterior vent
locations for both horizontal and vertical terminations. Clearances may only be reduced by means
approved by a regulatory authority.