14
Control panel functions
To access the heat level display
, press on the flame icon (top left).
To adjust the heat level settings (orange icon), press + (plus) or - (minus) icons to
increase or decrease the desired heat level.
Note:
Level 1 is regulated with a flow of approximately 1 lb or .45 kg of fuel per
hour and level 5 is regulated with a flow of approximately 4 lbs or 1.81 kg of fuel
per hour. The feed system is on when the flame icon becomes green.
To access the combustion air display: press on the fan icon (center left). To
adjust the incoming air to the burner, press the green icon + (plus) or - (mi-
nus) to increase or decrease the combustion chamber pressure related to
the pressure gauge (mini-helic).
Note: Setting 5 is set by default. Setting 1 to 10 are available for adjust-
ments. For more details, refer pressure gauge chapter and chart on page 20.
To access ash removal settings:
Press on the trash icon (bottom left) to adjust
the quantity of ash removed: Press the green icon + (plus) or - (minus) to increase
or decrease the fuel bed height in the burner. For more detail, refer to page 19.
Note:
Each type of pellet or agriculture fuel produces its own quantity of ash con
-
tent per hour. Setting 15 is set by default, setting 11 to 20 are available for adjust-
ments. The ash system is on when the trash icon becomes green.
Startup mode display
Normal operation display
The first start up display is SM 1 mode.
Note:
When SM1 is red, close all doors (main door or hopper).
When SM 1 is green, the first 4 minutes start-up mode will begin.
Note:
Only the combustion fan is running on SM 1
Then display SM 2 will appear and run for another 4 minutes for the wood pellets
fuel and 21 minutes for the agriculture fuel.
WARNING: Only the stop button (red) is active during the start up mode.
Note:
All motors is running on SM2 mode.