32
Troubleshooting
Open the right side door and unplug one of the two white wires
connected to the Thermo-disk 110F-20 (see image 33). If the
fans stop, replace the disk Thermo-110F.
T14- The unit is cold and fans are running
Image 33
Thermo-disk 110F-20
Thermo-disk 130F-20
T15- No 12 volts leading to the main board
A-
The green light is off (refer to image 37).
First unplug the unit from
the AC source.
Remove the cover on the converter, lift the plastic pin
using a very thin blade (refer to image 34). Loosen the case screw, (re-
fer to image 35), then lift up the box. Replace the 5 amp fuse, (refer to
image 36). Connect the unit to the AC source and verify that the green
light and the screen are lit. Replace the converter if the green light is
off.
B
-
Battery Trouble:
Check if the battery is charged and properly
connected on red and black terminal clips supplied with the unit (12.8
volts). If no abnormality on the battery and connections: Check the DC
area 15 amp fuse (see image 36) and replace if necessary.
These fuses and labor are not covered by warranty.
Image 34
Image 35
Pin
Phillips head screw
A noisy ash removal may need to be lubricated. Refer to chapter M3 on page 25.
T16- Ash removal system
Image 36
Fuses from AC sector
Fuse from DC sector
Green light
Image 37