Drive Controlled Pump
Parker Hannifin Corporation
Hydraulics Group
DCP Manual innen A4 UK.indd 06.11.17
64
Manual
Frame D Internal dynamic brake switch
Internal dynamic brake switch
Frame E Internal dynamic brake switch
Product Code
Motor Power
(kW/hp)
Brake Switch
Peak Current (A)
Peak Brake
Dissipation (kW/
PS)
Brake Switch
Continuous Cur-
rent (A)
Continuous Bra-
ke Dissipation
(kW/hp)
Minimum
Brake Resistor
Value Ω
20 s maximum, 30 % duty
400V Build Variant: 380-480V ±10 %, 50/60 Hz +5 % DC link brake voltage: 765 V
DCP33P5
1.1 / 1.5
1.5A
1.1 / 1.5
1
0.75 / 1
520
DCP34P5
1.5 / 2
2.2A
1.7 / 2.3
1.4
1.1 / 1.5
355
DCP35P5
2.2 / 3
2.9A
2.3 / 3
2
1.5 / 2
260
DCP37P5
3 / 4
4.3A
3.3 / 4.5
2.9
2.2 / 3
177
DCP3010
4 / 5
5.9A
4.5 / 5.5
3.9
3 / 4
130
DCP3012
5.5 / 7.5
7.8A
6 / 7.5
5.2
4 / 5
98
Product Code
Motor Power
(kW/hp)
Brake Switch
Peak Current (A)
Peak Brake
Dissipation (kW/
PS)
Brake Switch
Continuous Cur-
rent (A)
Continuous Bra-
ke Dissipation
(kW/hp)
Minimum
Brake Resistor
Value Ω
20 s maximum, 30 % duty
400V Build Variant: 380-480V ±10 %, 50/60 Hz +5 % DC link brake voltage: 765 V
DCP3016
7.5 / 10
10.8A
8.25 / 11.25
7.2
5.5 / 7.5
71
DCP3023
11 / 15
14.7A
11.25 / 15
9.8
7.5 / 10
52
Frame F Internal dynamic brake switch
Frame G Internal dynamic brake switch
Product Code
Motor Power
(kW/hp)
Brake Switch
Peak Current (A)
Peak Brake
Dissipation (kW/
PS)
Brake Switch
Continuous Cur-
rent (A)
Continuous Bra-
ke Dissipation
(kW/hp)
Minimum
Brake Resistor
Value Ω
20 s maximum, 30 % duty
400V Build Variant: 380-480V ±10 %, 50/60 Hz +5 % DC link brake voltage: 765 V
DCP3032
15 / 20
21.5A
16.5 / 22.5
14.4
11 / 15
35
DCP3038
18 / 25
29.4A
22.5 / 30
19.6
15 / 20
26
Product Code
Motor Power
(kW/hp)
Brake Switch
Peak Current (A)
Peak Brake
Dissipation (kW/
PS)
Brake Switch
Continuous Cur-
rent (A)
Continuous Bra-
ke Dissipation
(kW/hp)
Minimum
Brake Resistor
Value Ω
20 s maximum, 30 % duty
400V Build Variant: 380-480V ±10 %, 50/60 Hz +5 % DC link brake voltage: 765 V
DCP3045
22 / 30
36A
27 / 37.5
24
18 / 25
21
DCP3060
30 / 40
43A
33 / 45
29
22 / 30
17.7
DCP3073
37 / 50
59A
45 / 60
39
30 / 40
13
Frame J Internal dynamic brake switch
Product Code
Motor Power
(kW/hp)
Brake Switch
Peak Current (A)
Peak Brake
Dissipation (kW/
PS)
Brake Switch
Continuous Cur-
rent (A)
Continuous Bra-
ke Dissipation
(kW/hp)
Minimum
Brake Resistor
Value Ω
20 s maximum, 30 % duty
400V Build Variant: 380-480V ±10 %, 50/60 Hz +5 % DC link brake voltage: 765 V
DCP3087
45 / 60
73
5.5 / 75
49
37
10.5
DCP3105
55 / 75
88
67.5 / 90
59
45
8.7
DCP3145
75 / 100
108
82.5 / 112.5
72
55
7
Product Code
Motor Power
(kW/hp)
Brake Switch
Peak Current (A)
Peak Brake
Dissipation (kW/
PS)
Brake Switch
Continuous Cur-
rent (A)
Continuous Bra-
ke Dissipation
(kW/hp)
Minimum
Brake Resistor
Value Ω
20 s maximum, 30 % duty
400V Build Variant: 380-480V ±10 %, 50/60 Hz +5 % DC link brake voltage: 765 V
DCP3180
90 / 125
147
112.5 / 150
98
75 / 100
5.2
DCP3205
110 / 150
176
135 / 187.5
118
90 / 125
4.3
DCP3260
132 / 200
216
165 / 225
144
110 / 150
3.55
Internal brake switch Frame H Internal dynamic brake switch