Drive Controlled Pump
Parker Hannifin Corporation
Hydraulics Group
DCP Manual innen A4 UK.indd 06.11.17
18
Manual
1)
Not required (can be used to display)
Inputs – Analogue (DCP3xxxA)
Analogue / Digital Inputs
Inputs – Fieldbus (DCP3xxxC/D/E/P/N)
Analogue / Digital Inputs
Control wiring connections
Control word (2021)
Selected Hydraulic Application (Control Type)
Terminal
Q Control
p Control
p/Q Control
LS Control
Accumulator Control
ANIN01 (X11/01)
Pressure Feedback 1) Pressure Feedback
Pressure Feedback Pressure Feedback p0 Pressure Feedback
ANIN02 (X11/02)
Flow Setpoint
Pressure Setpoint
Flow Setpoint
Pressure Feedback
LS1
not used
ANIN11 (X21/02)
(optional)
not used
not used
Pressure Setpoint
Pressure Setpoint
not used
DIGIN01 (X13/02)
Start Drive
DIGIN02 (X13/03)
No Stop
DIGIN03 (X13/04)
Reset
DIGIN04 (X12/01)
Pump 1 On/Off
Switch On Signal
DIGIN05 (X12/02)
Pump 2 On/Off
Switch off Signal
DIGIN06 (X12/03)
Terminal used as DIGOUT 03
DIGIN07 (X12/04)
Terminal used as DIGOUT 04
Selected Hydraulic Application (Control Type)
Terminal
Q Control
p Control
p/Q Control
LS Control
Accumulator Control
ANIN01 (X11/01)
Pressure Feedback 1) Pressure Feedback
Pressure Feedback Pressure Feedback p0 Pressure Feedback
ANIN02 (X11/02)
not used
Pressure Feedback
LS1
not used
ANIN11 (X21/02)
(optional)
not used
DIGIN01 (X13/02)
not used
DIGIN02 (X13/03)
not used
DIGIN03 (X13/04)
not used
DIGIN04 (X12/01)
not used
Switch on Signal
DIGIN05 (X12/02)
not used
Switch off Signal
DIGIN06 (X12/03)
Terminal used as DIGOUT 03
DIGIN07 (X12/04)
Terminal used as DIGOUT 04
Selected Hydraulic Application (Control Type)
Bit
Q Control
p Control
p/Q Control
LS Control
Accumulator Control
0
Start Drive
1
No Stop
2
Reset
3
Pump 1 on/off
Switch on signal
4
Pump 2 on/off
Switch off signal
5..15
reserved