Drive Controlled Pump
Parker Hannifin Corporation
Hydraulics Group
DCP Manual innen A4 UK.indd 06.11.17
61
Manual
Electrical Ratings (400 V build variant), Frame E, F
Electrical Ratings (400 V build variant), Frame G
Power Supply = 380-480V ±10 %, 50/60 Hz ±5%
Motor power, output current and input current must not be exceeded under steady state operating conditions.
Minimum repetitive power up / power down cycle time = 10 min
Product Code
Motor Power
Output Current
(A)
Input Current
(A)
Estimated Effi-
ciency
Switching Frequency
(kHz)
nominal / maximum
Output Current Derate
%/kHz
Frame E: Input currents for kW ratings are at 400V 50Hz ac input and for Hp ratings at 460V 60Hz ac input. Prospective short circuit
current 5kA.
Normal Duty (Output Overload Motoring 110% for 60s)
DCP3016
7.5 kW
16
14.5
97 %
4 / 16
5.5 %
10 PS
14
12.1
DCP3023
11 kW
23
20.4
97 %
4 / 16
5.1 %
15 PS
21
18
Heavy Duty (Output Overload Motoring 150% for 30s, 180% for 0.3s short term rating)
DCP3016
5.5 kW
12
10.7
97 %
4 / 16
4.9 %
7.5 PS
11
9.5
DCP3023
7.5 kW
16
14.5
97 %
4 / 16
4.9 %
10 PS
14
12.7
Frame F : Input currents for kW ratings are at 400V 50Hz ac input and for Hp ratings at 460V 60Hz ac input. Prospective short circuit
current 5kA.
Normal Duty (Output Overload Motoring 110% for 60s)
DCP3032
15 kW
32
28.5
97 %
4 / 12
6.3 %
20 PS
27
24.5
DCP3038
18.5 kW
38
33.5
97 %
4 / 12
6.7 %
25 PS
36
30.2
Heavy Duty (Output Overload Motoring 150% for 60s, 180% for 0.3s short term rating)
DCP3032
11 kW
23
21.7
97 %
4 / 12
6.0 %
15 PS
21
19.1
DCP3038
15 kW
32
28.5
97 %
4 / 12
6.1 %
20 PS
27
24.5
Power Supply = 380-480V ±10 %, 50/60 Hz ±5%
Motor power, output current and input current must not be exceeded under steady state operating conditions. Minimum repetitive po-
wer up / power down cycle time = 10 min
Product Code
Motor Power
Output Cur-
rent (A)
Input Current
(A)
Estimated Ef-
ficiency
Switching Frequen-
cy (kHz)
nominal / maximum
Output Current Derate
%/kHz
Frame G : Input currents for kW ratings are at 400V 50Hz ac input and for Hp ratings at 460V 60Hz ac input. Prospective short circuit
current 10kA.
Normal Duty (Output Overload Motoring 110% for 60s)
DCP3045
22kW
45
40
98 %
3 / 12
5.7 %
30Hp
40
35.7
DCP3060
30kW
60
54.7
98 %
3 / 12
5.9 %
40Hp
52
48
DCP3073
37kW
73
66.2
98 %
3 / 12
5.6 %
50Hp
65
58.5
Heavy Duty (Output Overload Motoring 150% for 60s, 180% for 3s short term rating)
DCP3045
18kW
38
34.3
98 %
3 / 12
5.3 %
25Hp
36
30.5
DCP3060
22kW
45
41.8
98 %
3 / 12
5.7 %
30Hp
40
37.5
DCP3073
30kW
60
54.7
98 %
3 / 12
5.2 %
40Hp
52
48