Drive Controlled Pump
Parker Hannifin Corporation
Hydraulics Group
DCP Manual innen A4 UK.indd 06.11.17
51
Manual
Parameter list
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
Selected
App
1900 Selected Application
Setup::Application::App Selection
USINT
(enum)
0
0: Q CONTROL
CONFIG
ALL
1: p CONTROL
2: p/Q Control
3: LS Control
4: ACCUMULA-
TOR CONTROL
1901 Pump type
Setup::Application::Setup pump::Pump
type
String
DCP3xx-
xA0000
STOPPED
ALL
1904 Double Pump
Setup::Application::Setup
pump::Double pump
BOOL FALSE
STOPPED
ALL
1905 Displacement Pump1
Setup::Application::Setup pump::Displ.
Pump1
REAL
0
0 to 1000
CCM STOPPED
ALL
1906 Displacement Pump2
Setup::Application::Setup pump::Displ.
Pump2
REAL
0
0 to 1000
CCM STOPPED
ALL
1908 Pump Speed min RPM
Setup::Application::Setup pump::Pump
Speed Min
REAL
0
0 to 3000
RPM
ALWAYS
ALL
1909 Pump Speed max RPM
Setup::Application::Setup pump::Pump
Speed Max
REAL
1000
0 to 6000
RPM
ALWAYS
ALL
1912 Max pressure pump1
Setup::Application::Setup pump::Max
pressure pump1
REAL
0
0 to 500
BAR
ALWAYS
ALL
1913 Max pressure pump2
Setup::Application::Setup pump::Max
pressure pump2
REAL
0
0 to 500
BAR
ALWAYS
ALL
1917 Flow Setpoint
Monitor::Application::Q Control
REAL
0
0 to 1000
LPM
NEVER
Q , pQ
Monitor::Application::p/Q Control
1918 Flow Setpoint Fieldbus Monitor:Application:Fieldbus
REAL
0
0 to 1000
LPM
ALWAYS
Q , pQ
1919 Actual Flow
Monitor::Application::Q Control
REAL
0
0 to 1000
LPM
NEVER
Q , pQ
Monitor::Application::p/Q Control
1920 Flow window
Setup::Application::Q Control
REAL
0
0 to 1000
LPM
ALWAYS
Q , pQ
1921 Flow window time
Setup::Application::Q Control
TIME
0
0 to 60
S
ALWAYS
Q , pQ
1922 Qmax at 100% AIN02
Setup::Application::Analog Input Q
REAL
0
0 to 1000
LPM
ALWAYS
Q , pQ
Setup::Application::Analog Input pQ
1923 Flow reached
Monitor::Application::Digital IOs
BOOL FALSE
NEVER
LS
1924 Leakage Comp. Flow
Favourites
REAL
0
0 to 100
LPM
NEVER
ALL
1930 Pressure Setpoint
REAL
0
0 to 500
BAR
NEVER p, p/Q. LS
Monitor::Application::p Control
Monitor::Application::p/Q Control
Monitor::Application::LS Control
1931
Pressure Setpoint Field-
bus
Monitor:Application:Fieldbus
REAL
0
0 to 500
BAR
ALWAYS p, p/Q. LS
1932 Actual pressure p0
Monitor::Application::Q Control
REAL
0
0 to 500
BAR
NEVER
ALL
Monitor::Application::p Control
Monitor::Application::p/Q Control
Monitor::Application::LS Control
Monitor::Application::Accu Control
1933 Pressure window
Setup::Application::p Control
REAL
0
0 to 500
BAR
ALWAYS p, p/Q. LS
Setup::Application::p/Q Control
Setup::Application::LS Control
1934 Pressure window time
Setup::Application::p Control
TIME
0
0 to 60
S
ALWAYS p, p/Q. LS
Setup::Application::p/Q Control
Setup::Application::LS Control
1935 Pressure ramp up
Setup::Application::p Control
REAL
0
0 to 10000
BAR
ALWAYS p, p/Q. LS
Setup::Application::p/Q Control
Setup::Application::LS Control
1936 Pressure ramp down
Setup::Application::p Control
REAL
0
0 to 10000
BAR
ALWAYS p, p/Q. LS
Setup::Application::p/Q Control
Setup::Application::LS Control
1937 P amx at 100%
Setup::Application::Analog Input p
REAL
0
0 to 500
BAR
ALWAYS p, p/Q. LS
Setup::Application::Analog Input pQ
Setup::Application::Analog Input LS