The Display
• The top line of the display is used to show the drive
status
• The central region of the display shows the selected
parameters or navigation menu
• The bottom line of the display indicates the action as-
sociated with the soft keys
• The actions of the soft keys are context dependent
• The central navigation and editing keys are referred to
as UP, DOWN, LEFT, RIGHT and OK
• The Run, (green), and Stop, (red), keys are used to
start and stop the motor when the drive is in local con-
trol mode.
Keys
The nine keys of the Graphical Keypad are divided into three groups. These are the Run and Stop keys, the soft
keys and the central navigation and editing keys
Key
Operation Description
RUN
Only operates when Local start / stop control mode is active
Control Runs the motor
STOP
Control Stops the motor when local start / stop control mode is active. Trip reset Resets any trips.
Softkey 1
Navigation Displays the previous level’s menu
Edit Aborts the edit, leaving the value unchanged
Softkey 2
Changes the Local/Remote Mode selection
OK
Navigation Displays the next menu level or parameter. Changes to edit mode when a parameter is selected.
Edit Accepts the value of the displayed parameter Long Press, (greater than 1s): Displays information about the
selected parameter.
UP
Navigation Moves up through the list of parameters
Edit Increments the value of the displayed parameter
DOWN
Navigation Moves down through the list of parameters
Edit Decrements the value of the displayed parameter
LEFT
Navigation Displays the previous level’s menu
Edit Selects the digit to be changed
RIGHT
Navigation Displays the next menu level or parameter
Edit Selects the digit to be changed
Softkey 1
Softkey 1