Drive Controlled Pump
Parker Hannifin Corporation
Hydraulics Group
DCP Manual innen A4 UK.indd 06.11.17
17
Manual
Control wiring connections
Control Wiring Layout Diagram
Terminal Cable Specification
Solid minimum H05(07)V-U 0.2 mm
2
.
Solid maximum H05(07)V-U 1.5 mm
2
.
Flexible minimum H05(07)V-K 0.2 mm
2
.
Flexible maximum H05(07)V-K 1.5 mm
2
.
W.wire end Ferrule DIN462228 Pt 1 minimum 0.25 mm
2
.
W.wire end Ferrule DIN462228 Pt 1 maximum 1.5 mm
2
.
W.plastic collar Ferrule DIN462228 Pt4 minimum 0. 25 mm
2
.
W.plastic collar Ferrule DIN462228 Pt4 maximum 0.75 mm
2
.
Terminal ID
Function
X10/01
STO A Input
X10/02
STO Common
X10/03
STO B Input
X10/04
STO Common
X10/05
STO Status A
X10/06
STO Status B
X11/01
Anin 01 (+10V, 0-10V, 0-20mA, 4-20mA)
X11/02
Anin 02 (+10V, 0-10V)
X11/03
Anout 01 (+10V, 0-10V)
X11/04
Anout 02 (0-10V, 0-20mA, 4-20mA)
X11/05
+10V reference
X11/06
-10V reference
X12/01
Digin 04 / Digout 01
X12/02
Digin 05 / Digout 02
X12/03
Digin 06 / Digout 03
X12/04
Digin 07 / Digout 04
X12/05
User +24V output
X12/06
0 V
X13/01 (LH)
0 V
X13/02
DIGIN 1
X13/03
DIGIN 2
X13/04
DIGIN 3
X13/05
+24V AUX input
X13/06
0V AUX input
X14/01 (BOT)
Relay 01 (contact A)
X14/02
Relay 01 (contact B)
X14/03
Relay 02 (contact A)
X14/04
Relay 02 (contact B)