Chapter 1. Installation
2 1
STATUS LEDs
AUX
Board
Computer
After power up, the DISABLED status LEDs will be red until
you issue the
DRIVE1111
command to enable the drives,
at which time the LEDs will turn off. These LEDs will again
turn red if the drives are shut downÑpossible causes are:
¥ Shutdown was commanded with the
DRIVE
command.
¥ Drive fault input (DFT) is active.
¥ Enable input (ENBL) is not grounded.
¥ Maximum allowable position error (set with the
SMPER
command value) is exceeded.
¥ Kill command (
K
,
!K
or
<CTRL>K
) was issued, or a Kill
input or user fault input was activated while the Disable
Drive on Kill feature was enabled (refer to the
KDRIVE
command).
When power is applied, the status LED on the AT6n50
card will be off and the status LED on the auxiliary board
should be red. If the LED on the auxiliary board is off,
the auxiliary board does not have AC power. After the
operating system is downloaded, the status LEDs on the
auxiliary board and the AT6n50 card will turn green
indicating the system is ready for operation. If both status
LEDs do not turn green after downloading the operating
system, an error has occurred. The operating system
downloader (Motion Architect or the AT6250.EXE or
AT6450.EXE program from your DOS support disk)
issues an error message if it cannot find the card or if the
download operation is not successful (refer the
Downloading Error table on page 31).
RED: Receiving power from AT bus.
OFF: No power.
ANI Option Card Only
Green: High density cable connected
OFF: Cable not connected properly
Lengthening I/O Cables
Bear in mind that lengthening cables increases noise sensitivity. (The maximum length of
cables is ultimately determined by the environment in which the equipment will be used.)
If you lengthen the cables, follow the precautions below to minimize noise problems.
¥ Use a minimum wire size of 22 AWG.
¥ Use twisted pair shielded cables and connect the shield to a
SHLD
terminal on an AUX
board. Leave the other end of the shield disconnected.
¥ Do not route I/O signals in the same conduit or wiring trays as high-voltage AC wiring.
Reducing noise on limit (
H O M
,
C W
&
C C W
), trigger (
T R G - x
), drive fault (
D F T
) ,
and enable (
ENBL
) inputs.
If you are experiencing noise problems, try adding resistors to
reduce noise sensitivity (see illustration below).
Long Shielded Cable
Add a resistor between the input and the power supply
(this will lower the input impedance and reduce noise
sensitivity). Use a value between 330
W
and 2.2K
W
,
depending on noise suppression required.
Output Device,
Switch, etc.
Input Terminal
GND
Shield
AUX Board
+5V
Isolated
Ground
Earth
Terminal could be:
HOM, CW, CCW,
TRG-x, DFT, or ENBL
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание Compumotor 6000 Series
Страница 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 7: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 33: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 53: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 57: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...