9-22
Function Parameters
AC10 Inverter
9.3.2 Digital multifunctional input terminals
F316 DI1 terminal function setting
Setting range:
0: no function
1: Run
2: Stop
3: multi-stage speed 1
4: multi-stage speed 2
5: multi-stage speed 3
6: multi-stage speed 4
7: reset 8: free stop
9: external coast stop
10: acceleration/deceleration forbidden
11: forward run jogging
12: reverse run jogging
13: UP frequency increasing terminal
14: DOWN frequency decreasing terminal
15: “FWD” terminal
16: “REV” terminal
17: three-line type input “X” terminal
18: acceleration/deceleration time
switchover 1
19: Reserved
20: switchover between speed and torque
21: frequency source switchover terminal
32: Fire pressure switchover
33: Emergency fire control
34: Acceleration / deceleration switchover 2
37: Common-open PTC heat protection
38: Common-close PTC heat protection
48: High-frequency switchover
52: Jogging (no direction)
53: Watchdog
54: Frequency reset
55: Switchover between manual running and
auto running
56: Manual running
57: Auto running
58: Direction
Mfr’s value: 11
F317 DI2 terminal function setting
Mfr’s value: 9
F318 DI3 terminal function setting
Mfr’s value: 15
F319 DI4 terminal function setting
Mfr’s value: 16
F320 DI5 terminal function setting
Mfr’s value: 7
This parameter is used for setting the corresponding function for multifunctional digital input
terminal.
Both free stop and external coast stop of the terminal have the highest priority.
Table 9-3 Instructions for digital multifunctional input terminal
Value Function
Instructions
0
No function
Even if signal is input, inverter will not work. This
function can be set by undefined terminal to
prevent mistake action.
1
Running terminal
When running command is given by terminal or
terminals combination and this terminal is valid,
inverter will run. This terminal has the same
function with “Run” key in keypad.
2
Stop terminal
When stop command is given by terminal or
terminals combination and this terminal is valid,
inverter will stop. This terminal has the same
function with “stop” key in keypad.
TC-Hydraulik - R