13-3
The Default Applications
AC10 Inverter
This Application is ideal for general purpose applications. The set-point is the sum of the two
analogue inputs AI1 and AI2, providing Speed Set-point + Speed Secondary capability.
Application 1 : Basic Speed Control
Parameters Setting:
F228 = 1
F106 = 2
F203 = 1
F204 = 2
F207 = 1
F316 = 1
F317 = 58
F318 = 52
F319 = 2
F320 = 8
F431 = 0
Coast stop
1
2
3
5
6
4
7
8
9
10
11
12
13
14
15
16
17
18
TA
TB
TC
1
DO
24
V
CM
DI1
DI2
DI3
DI4
DI5
10
V
1
AI
2
AI
GND
1
AO
A
+
B
-
REF
Stop
Jog
Direction
Run
Speed trim
not used
not used
Analog output F431=0, running
frequency is output.
GND
Speed trim AI2 input 4-20 mA
Speed setpointAI1 input 0-10V
10V
Coast stop
Stop
Jog
The jogging direction is
controlled by DI2.
Direction
When the function is valid,
inverter runs reverse
Run
CM
24V
not used
Relay output