13-7
The Default Applications
AC10 Inverter
This is ideal for applications requiring multiple discrete speed levels.
The set-point is selected from either the sum of the analogue inputs, or as one of up to eight
other pre-defined speed levels. These are selected using DI2, DI3 and DI4, refer to the Truth
Table below.
Preset Speed Truth Table
DI4
DI3
DI2
Preset
Application 3: Preset Speeds
Parameters Setting:
F223 = 3
F106 = 2
F203 = 4
F204 = 1
F207 = 1
F316 = 56
F317 = 3
F318 = 4
F319 = 5
F320 = 8
F431 = 0
0V
0V
0V
1
0V
0V
24V
2
0V
24V
0V
3
0V
24V
24V
4
24V
0V
0V
5
24V
0V
24V
6
24V
24V
0V
7
24V
24V
24V
8
Coast stop
1
2
3
5
6
4
7
8
9
10
11
12
13
14
15
16
17
18
TA
TB
TC
1
DO
24
V
CM
DI1
DI2
DI3
DI4
DI5
10
V
1
AI
2
AI
GND
1
AO
A
+
B
-
REF
Run forward
Speed trim
not used
not used
Analog output F 431=0 , running
frequency is output
.
GND
Speed trim AI2 input 4-20 mA
Speed setpoint AI 1 input 0-10V
10V
Coast stop
Preset select 1
Auto run
CM
24V
not used
Relay output
See truth table below
F 300=1 , inverter outputs
fault signal.
See truth table below
Preset select 2
Preset select 3
See truth table below
Preset select 1
Preset select 2
Preset select 3