F600
DC Braking Function Selection
0: Invalid;
1: braking before starting;
2: braking during stopping;
3: braking during starting and stopping
0
√
F601
Initial Frequency for DC Braking
0.20
~
50.00
1.00
√
F602
DC Braking efficiency before Starting
0
~
100
10
√
F603
DC Braking efficiency During Stop
0
~
100
10
√
F604
Braking Lasting Time Before Starting
0.00
~
30.00
0.50
√
F605
Braking Lasting Time During Stopping
0.00
~
30.00
0.50
√
F606
Reserved
F607
Selection of Stalling Adjusting Function
0: invalid;
1: valid
2: Reserved
3: Voltage current control
4: Voltage control
5: Current control
0
√
F608
Stalling Current Adjusting (%)
60
~
200
160
√
F609
Stalling Voltage Adjusting (
%
)
110
~
200
1 phase: 130
3 phase: 140
√
F610
Stalling Protection Judging Time
0.1
~
3000
60.0
√
F611
Dynamic Braking Threshold (V)
200~1000
Subject to
inverter
model
△
F612
Dynamic Braking Duty Ratio (%)
0
~
100
%
80
╳
F613
Flycatching
0: invalid
1: valid
2: valid at the first time
0
╳
F614
Flycatching Rate Mode
0: Flycatching from frequency
memory
1: Flycatching from max frequency
2: Flycatching from frequency
memory and direction memory
3: Flycatching from max frequency
and direction memory
0
╳
F615
Flycatching Rate
1
~
100
20
╳
F613 –
F621
Reserved
F622
Dynamic Braking Mode
0: Fixed duty ratio
1: Auto duty ratio
0
√
F627
Current Limiting when Flycatching
50-200
100
╳
F631
VDC Adjustment Selection
0: invalid