21
LT6523 ( Iss 4 10/14 )
P8 Installation Instructions
SECTION NINE To Install the Appliance Continued
FIT LINERS (See Page 9)
LAY FUEL BED
Important: -
Refer to the ‘Heath & Safety Notice located on page 3 of this booklet before laying or replacing any refractory material.
In the event of replacing fuel bed components please use only the specified number of components as illustrated. Only
use fuel bed component provided for this appliance. In the interest of safety and efficiency of your appliance when
replacing the fuel bed it is essential that the existing fuel bed be removed and the new components are replaced correctly
as a complete set.
Lay fuel bed as described under Users Section.
Warning:
It is important that the fuel bed components are positioned as shown in these instructions.
If the fuel bed components are not positioned correctly this may result in damage to the glass.
P8Installation Instructions
SECTION TEN Checking Operation of Fire
CHECKING FOR COMBUSTION PRODUCTS CLEARENCE
IMPORTANT
:-The smoke test must be carried out with the fire starting from cold.
Light the fire and leave at maximum input.
Close all the doors and windows.
After five minutes fit the smoke match in a holder and position
as illustrated with the head of the match just inside the test
opening.
Run the match along the top edge
All smoke
must be drawn
into the test opening if the clearance is satisfactory.
If spillage occurs wait a further five minutes and repeat the
test.
Repeat the test with doors open and with any extractor fans
in other rooms in operation.