20
LT6523 ( Iss 4 10/14 )
Place the Glass panel within the location bracket within the fire box shelf assembly.
P8 Installation Instructions
SECTION NINE To Install the Appliance continued
Retain the glass panel by using the glass
fixing bracket and nuts provided.
Connect the battery pack as described in
section one with the insulation sleeve
provided. Place on the fire box base along
the front edge on the left hand side.
Fit the trim bottom cover along the bottom
edge of the shelf assembly using the 2 off
fixing pins provided.
Position the loose magnet against the
inner return of the four sided trim
assembly.
Locate the remote receiver eye within the
clip located at the bottom edge of the trim
making sure the complete curved face is
projecting clear of the bottom trim edge.
Offer the trim up against the firebox, with
the top return of the trim rest upon the top
of the fire box flange.
P8Installation Instructions
SECTION NINE To Install the Appliance Continued
CHECKING GAS SOUNDNESS AND RUNNING PRESSURE.
Turn on the gas supply to the appliance and check for soundness in accordance with current codes of practice.
Turn off the gas supply at the external Isolation valve.
Remove the pressure test point screw from the inlet elbow and connect the pressure gauge.
Turn on the gas to the appliance at the Isolation valve.
Light the appliance as described in section 2.
Check the inlet pressure is 20mbar. +/- 2.0 /- 2.0
Turn off gas supply, at the isolation valve. Disconnect the pressure gauge and replace the pressure test point screw.
Turn on the supply to the appliance and check the pressure test point for soundness with detection fluid.
Refit the gas connection cover.
Fit the air tray within the location with the burner shelf.
Construction of a false chimney breast front.
Using 50mm K.D Sawn stud-work will provide the required rebate.
The vertical sides of the stud-work should not be less than 502mm from the centre of the firebox. The horizontal
stud-work should not be less than 764mm from the base of the firebox. This will ensure 50mm minimum
clearance from the sides and 110mm clearance from the top of the firebox is maintained.
An insulation material (20mm “Super lux” or equivalent) should be attached to the underside face of the horizontal
stud-work directly above the firebox assembly.
Line the opening with 12mm thick non-combustible material.