background image

Model 2100PKN 2100PKP 2200KN

2200LNK

2200RKN

2200KP

2200LKP

2200RKP

Gas

Natural

Propane

Natural

Propane

Altitude (Ft.)

0-4,500 feet

Input Maximum (Btu/h)

25,000

25,000

36,000

36,000

Input Minimum (Btu/h)

14,000

14,000

19,000

21,000

Manifold Pressure (in w.c.)

3.5”

10”

4.0”

9.5”

Minimum Supply Pressure (in w.c.)

5”

11”

5”

11”

Maximum Supply Pressure (in w.c.)

10”

14”

10”

14”

Main Burner Injector Marking

DMS#42

DMS#53

DMS#32

DMS#49

Pilot Injector Marking

51

30

51

30

Min. Rate By-Pass Screw

185

125

220

160

General notes regarding conversion

We recommend that the gas conversion be done before the appliance is inserted in 

fi

 nal position into the cavity, 

although it may be done after. The gas must be connected in order to set the manifold pressure.

WARNING

This conversion kit shall be installed by 

a qualified service agency in accordance 

with the manufacturer’s instructions and 

all applicable codes and requirements 

of the authority having jurisdiction. If 

the information in these instructions is 

not followed exactly, a fire, explosion 

or production of carbon monoxide may 

result causing property damage, personal 

injury or loss of life. The qualified service 

agency is responsible for the proper 

installation of this kit. The installation 

is not proper and complete until the 

operation of the converted appliance is 

checked as specified in the manufacturer’s 

instructions supplied with the kit.
Use this manual in conjunction with the 

installation manual supplied with the 

appliance.

LX1 (2100NGK / 2100PGK) 

LX2 (2200XNGK / 2200XPGK)

Gas Conversion Kits

INSTALLATION INSTRUCTIONS

LX Series

Use with Valor 2100PKN/PKP, 2200KN/KP, 2200LKN/LKP, and 2200RKN/RKP heaters ONLY

4007021-02

This appliance is certi

fi

 ed for use from 0–4,500 feet. For 

altitudes above 4,500 feet, see local codes.

Kit Contents

• 1 Pilot injector

• 1 Main burner injector

• 1 Set of conversion labels

• 1 bypass screw

Tools Required

•  Wrenches, to disconnect gas line

•  Small (jewelers size) 

fl

 at blade screwdriver, to set pres-

sure

• Small 

fl

 at blade screwdriver, to release pressure tap 

on valve

•  Needle nose pliers, to remove by-pass screw

•  Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot injec-

tor

•  Manometer, to set manifold pressure at the valve

•  Appliance’s installation manual

Speci

fi

 cations

© Copyright Miles Industries Ltd., 2019

Содержание LX Series

Страница 1: ...ction of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not...

Страница 2: ...rear 2 screws each for LX1 3 screws each for LX2 Gas shut o valve LX2 Top view LX1 Top view Gas shut o valve Access panel Access panel Access panel removed LX2 LX1 Top view LX2 Top view 5 Remove the b...

Страница 3: ...cess hatch in the front panel of the appliance Remove and replace the mini mum rate bypass screw from the valve with the appropriately labelled bypass screw see Specifications table on page 1 The scre...

Страница 4: ...ver to slide the shutter left or right Complete the installation of the fireplace Complete the installation of the fireplace following the guidelines of the installation instructions supplied with the...

Страница 5: ...e de carbone pourraient se produire et causer des dommages mat riels des blessures ou la mort L agence de service qualifi e pour effectuer cette installation est responsible de l installation appropri...

Страница 6: ...plateau du lit de combustion LX1 4 vis LX2 6 vis Panneau d acc s Panneau d acc s enlev LX1 Vu du haut LX2 Vu du haut 5 Enlevez le br leur LX1 4 vis LX2 6 vis Avec pr cautions tirez le br leur vers la...

Страница 7: ...pas pos e Si elle est pos e vous devez enlever la plaque du br leur pour y avoir acc s Enlevez la vis d indice minimum de la soupape et remplacez la par la vis appropri e voir le tableau Indices sign...

Страница 8: ...propri e Avec la lame d un toun evis pliez l onglet indiqu vers le bas ou soulevez la selon le type de gaz utilis 2 R glez l obturateur utilisant un tounevis pour bouger le levier vers la droite ou la...

Отзывы: