Digiplex/DigiplexNE LCD Keypad 31
n
6.4.6 B
EEP
T
IMER
F
OR
D
OOR
L
EFT
O
PEN
A
LARM
S
ECTION
[012]
This beep timer determines the amount of time the Door Left
Open Alarm will beep. Once the Door Left Open Interval (see
section 6.4.2 on page 29) has expired, the Door Left Open
Alarm (see section 6.4.5 on page 30) will be triggered. Enter
any value between 001 and 255 to determine the number of
seconds the Access Alarm will beep. Default = 5 seconds.
6.5 DOOR FORCED OPEN OPTIONS
The Door Forced Open Options allow you to program how the
system will react when an Access Control door is opened without a
“Request for Exit” or “Access Granted” signal.
6.5.1 D
OOR
F
ORCED
O
PEN
A
CCESS
A
LARM
S
ECTION
[006]: O
PTION
[3]
If an Access Control door is opened without an Access Control
Card, a User Access Code or receiving a Request for Exit, an
Access Alarm can be generated. A Burglar Alarm can also be
generated. When the door is closed during an Access Alarm,
the Door Forced Open Restore event can be logged in the
Event Buffer.
Option [3] OFF= Door Forced Open Alarm is disabled (default).
Option [3] ON = Door Forced Open Alarm is enabled.
When the Door Forced Open Alarm is disabled, the following
sections are also disabled:
Section
[004] O
PTION
[7] D
OOR
F
ORCED
O
PEN
A
LARM
O
PTION
[8] D
OOR
F
ORCED
O
PEN
A
LARM
FOLLOWS
[013]
B
EEP
T
IMER
FOR
D
OOR
F
ORCED
O
PEN
A
LARM
Содержание DGP2-641
Страница 1: ...LCD Access Control LCD Keypad V1 0 DGP2 641 DGP2 641AC Reference and Installation Manual...
Страница 10: ...8 Reference Installation Manual Figure 1 Connecting the Keypad and Keypad Zone...
Страница 12: ...10 Reference Installation Manual Figure 4 Access Control Connections DGP2 641AC...
Страница 13: ...Digiplex DigiplexNE LCD Keypad 11n Figure 5 Connecting a Shielded Routing Cable...
Страница 38: ...36 Reference Installation Manual Table 2 Special Characters Catalog...
Страница 43: ......
Страница 44: ...PRINTED IN CANADA 04 2002 DGP2641 EI07...