Digiplex/DigiplexNE LCD Keypad 25
n
6.2.4 R
EADER
'
S
LED O
PTIONS
U
PON
A
CCESS
G
RANTED
S
ECTION
[006]: O
PTION
[7]
When the Access Control card is presented to the reader, the
reader's LED can be programmed to turn green during the
door’s unlocked period (or until the door closes) or extinguish
briefly to indicate that the door is unlocked.
Option [7] OFF= The reader's red LED will extinguish briefly.
Option [7] ON = The reader's red LED will turn green (default).
6.3 DOOR LOCK OPTIONS
The Door Lock Options allow you to program the door lock to suit its
environment or security requirements.
6.3.1 U
NLOCK
ON
REX (R
EQUEST
F
OR
E
XIT
)
S
ECTION
[006]: O
PTION
[8]
When the REX device detects movement, it can permit
passage with or without turning the door handle. If this option
is on, the door is unlocked when the REX device detects
movement and users on either side of the door will be able to
open the door. If this option is off, the door will unlock once the
handle is turned only on the REX device’s side.
Option [8] OFF= Unlock on REX disabled (default).
Option [8] ON = Unlock on REX enabled.
6.3.2 D
OOR
U
NLOCKED
P
ERIOD
S
ECTION
[008]
The Door Unlocked Period is the time the door can remain
unlatched after access is granted or after a Request for Exit is
received. Enter any value between 001 and 255 to determine
the seconds the door can remain unlatched. Default = 5
seconds.
Содержание DGP2-641
Страница 1: ...LCD Access Control LCD Keypad V1 0 DGP2 641 DGP2 641AC Reference and Installation Manual...
Страница 10: ...8 Reference Installation Manual Figure 1 Connecting the Keypad and Keypad Zone...
Страница 12: ...10 Reference Installation Manual Figure 4 Access Control Connections DGP2 641AC...
Страница 13: ...Digiplex DigiplexNE LCD Keypad 11n Figure 5 Connecting a Shielded Routing Cable...
Страница 38: ...36 Reference Installation Manual Table 2 Special Characters Catalog...
Страница 43: ......
Страница 44: ...PRINTED IN CANADA 04 2002 DGP2641 EI07...