background image

6 Reference & Installation Manual

2.0 INSTALLATION

The LCD keypads (DG2P-641 and DGP2-641AC) are connected to
the control panel's network in a star and/or daisy chain configuration.
This 4-wire communication network provides power and two-way
communication between the control panel and all modules connected
to it. Connect the four terminals labeled red, black, green and yellow
of each keypad to the corresponding terminals on the control panel
(refer to Figure 1 on page 8). Refer to the Digiplex or DigiplexNE
Reference & Installation Manual
 for the maximum allowable
installation distance from the control panel. 

See Figure 4 on page 10 for connection drawings for the REX
device, reader, locking device and door contact to the desired DGP2-
641AC keypad. A typical installation is shown in Figure 2 on page 9.

The door contact follows the control panel’s EOL
definition. When EOL is enabled and the door contact is
not used, place a 1k

Ω 

resistor across the keypad’s Z1

and BLK input terminals. If EOL is not enabled, use a
jumper. If the REX device is not used, place a jumper
across the keypad’s Z2 and BLK input terminals.

2.1 CONNECTING KEYPAD ZONES

Each keypad has one traditional hardwired input terminal, allowing
you to connect one detector or door contact directly to the keypad.
For example, a door contact located at the entry point of an
establishment can be wired directly to the input terminal of the entry
point keypad instead of wiring the door contact all the way to the
control panel.

Connect the device to the keypad's input terminal as shown in Figure
1 on page 8. In order to communicate its status to the control panel,
devices connected to the keypad's input terminal must be assigned

Содержание DGP2-641

Страница 1: ...LCD Access Control LCD Keypad V1 0 DGP2 641 DGP2 641AC Reference and Installation Manual...

Страница 2: ...2002 Paradox Security Systems Ltd Digiplex and DigiplexNE are trademarks of Paradox Security Systems PosiPIN is a trademark of Position Technology...

Страница 3: ...13 3 2 1 Feature Select Programming 13 3 2 2 Decimal Programming 13 3 3 Module Broadcast 13 4 0 SYSTEM OPTIONS 14 4 1 Partition Assignment 14 4 2 Display Access Code Entry 14 4 3 Display Exit Delay Ti...

Страница 4: ...4 6 2 2 Reader s Beep To Follow Partition s Status 24 6 2 3 Reader Feedback 24 6 2 4 Reader s LED Options Upon Access Granted 25 6 3 Door Lock Options 25 6 3 1 Unlock on REX Request For Exit 25 6 3 2...

Страница 5: ...1 6 5 1 Door Forced Open Access Alarm 31 6 5 2 Door Forced Open Feedback 32 6 5 3 Beep Timer For Door Forced Open Alarm 32 6 6 Access Control PIN Entry Option 32 6 6 1 Configuring The PosiPIN s Keypad...

Страница 6: ...ess for up to 32 designated doors without the need of an additional control panel The events that occur on an Access Control door can be logged in the control panel s Event Buffer and can be viewed th...

Страница 7: ...and yellow LEDs flash simultaneously Network fault indication Red and yellow LEDs flash alternately Tamper Switch Yes also used to deactivate locate LCD Super Twisted Nematic display STN wide viewing...

Страница 8: ...ad A typical installation is shown in Figure 2 on page 9 The door contact follows the control panel s EOL definition When EOL is enabled and the door contact is not used place a 1k resistor across the...

Страница 9: ...on device 2 2 PROGRAMMABLE OUTPUT Each keypad has one on board PGM A PGM is a programmable output that toggles to its opposite state i e a normally open PGM will close when a specific event has occurr...

Страница 10: ...8 Reference Installation Manual Figure 1 Connecting the Keypad and Keypad Zone...

Страница 11: ...Digiplex DigiplexNE LCD Keypad 9n Figure 2 Typical Access Control Installation DGP2 641AC Figure 3 Access Control Overview DGP2 641AC...

Страница 12: ...10 Reference Installation Manual Figure 4 Access Control Connections DGP2 641AC...

Страница 13: ...Digiplex DigiplexNE LCD Keypad 11n Figure 5 Connecting a Shielded Routing Cable...

Страница 14: ...paradox ca 3 1 ENTERING MODULE PROGRAMMING MODE The keypad like all other modules in the system is programmed through the control panel To do so you must first enter the Module Programming Mode Step...

Страница 15: ...d In this method any digit from 000 to 255 can be entered 3 3 MODULE BROADCAST The control panel s Module Broadcast feature can be used to copy the contents of one keypad to one or many other keypads...

Страница 16: ...desired partition By default partitions 1 to 8 are enabled Section 001 options 5 to 8 can only be used if the keypad is connected to a DigiplexNE DGP NE96 control panel 4 2 DISPLAY ACCESS CODE ENTRY...

Страница 17: ...time the LCD screen will appear as shown in Figure 6 page 16 and the AC and STATUS LED will be off until either a button is pressed or an access code is entered The period of time in which no action i...

Страница 18: ...es the amount of time without action before the keypad enters Confidential Mode For more information on Confidential Mode refer to Confidential Mode on page 15 The Confidential Mode Timer can be set f...

Страница 19: ...nds it will beep more rapidly to provide a final warning before the area is armed Option 2 OFF Exit Delay beep disabled Option 2 ON Exit Delay beep enabled default 4 10 CHIME ON ZONE CLOSURE SECTION 0...

Страница 20: ...ition re occurs By default options 1 to 4 are OFF Option 1 OFF Beep disabled System Troubles and Clock Loss Option 1 ON Beep enabled System Troubles and Clock Loss Option 2 OFF Beep disabled Communica...

Страница 21: ...reading of 10 5V indicates that the voltage is too low This may occur when too many modules are connected to the network a module is installed too far from the panel or if the system is running on th...

Страница 22: ...and disable any devices connected to it When the PGM Activation Event occurs see section 5 6 the PGM will switch to its opposite state i e open to closed or closed to open Option 1 OFF PGM is Normall...

Страница 23: ...ation Events section 5 7 page 22 and PGM Timers section 5 5 page 21 It will remain in its normal state until the PGM Override is disabled This option may be used to test the PGM connections Option 4 O...

Страница 24: ...ired data 5 7 PGM DEACTIVATION EVENT SECTIONS 013 TO 016 If the PGM Deactivation Option section 5 2 on page 20 is set to follow the PGM Deactivation event the PGM will return to its normal state when...

Страница 25: ...section 4 1 on page 14 but the door is assigned to Partition 2 When the user presents the Access Control Card to the door s reader to arm the partition only Partition 2 will arm Option 1 ON door assi...

Страница 26: ...ION 003 OPTION 7 This feature will only function when section 003 option 6 is enabled The reader can be programmed to beep according to its keypad s beep when the partition assigned to the door is arm...

Страница 27: ...ments 6 3 1 UNLOCK ON REX REQUEST FOR EXIT SECTION 006 OPTION 8 When the REX device detects movement it can permit passage with or without turning the door handle If this option is on the door is unlo...

Страница 28: ...d during the Door Unlocked Period see section 6 3 2 on page 25 but once the door is opened it can be programmed to latch as soon as the door closes or latch immediately even if the door has not closed...

Страница 29: ...n 7AM and 4PM and on Saturday Sunday and Holidays between 10AM and 5PM Therefore users will not have to present their Access Control Cards during the Door Unlocked Schedule 6 3 6 CARD ACTIVATES DOOR U...

Страница 30: ...ESS ALARM SECTION 006 OPTION 2 When an Access Control door is opened after an Access Granted or a Request for Exit an Access Alarm can be generated if it not closed within a certain period of time see...

Страница 31: ...ert users that the Access Control door was left open and will generate an Access Alarm if it is not closed The Pre Alarm beeps slower than the Door Left Open Alarm about twice every second Program the...

Страница 32: ...rm is occurring or follow the Beep Timer in section 012 The sound of the Door Left Open Alarm resembles the rapid beep generated during the last ten seconds of the Exit Delay When the door is closed d...

Страница 33: ...Control door is opened without a Request for Exit or Access Granted signal 6 5 1 DOOR FORCED OPEN ACCESS ALARM SECTION 006 OPTION 3 If an Access Control door is opened without an Access Control Card...

Страница 34: ...Timer section 013 6 5 3 BEEP TIMER FOR DOOR FORCED OPEN ALARM SECTION 013 This Beep Timer determines the amount of time the Door Forced Open Alarm see section 6 5 2 above will beep Enter any value be...

Страница 35: ...pad communication format must be set to 8 bit Wiegand To do so from the PosiPIN perform the following Step 1 Press and hold the CLEAR key for 4 seconds the reader emits a confirmation beep and the gre...

Страница 36: ...201 to 204 First Area Second Area Third Area and Fourth Area respectively Section 301 to 396 Code 01 to Code 96 respectively After entering the section corresponding to the desired message use the Me...

Страница 37: ...Pressing the FORCE key will delete the character or blank space found at the current cursor position ARM Delete Until the End Pressing the ARM key will delete all characters and spaces to the right o...

Страница 38: ...36 Reference Installation Manual Table 2 Special Characters Catalog...

Страница 39: ...l A tag assigned to a User Access Code used to card identify the user to the Access Control system By presenting the tag to a reader the system can verify whether the tag is valid see Valid Access Con...

Страница 40: ...rd Display see Digiplex or DigiplexNE Reference Installation Manual The Access Control events however can only be viewed through an Access Control Keypad DGP2 641AC Forced Door If a protected door was...

Страница 41: ...trol card presented to it to the control panel Request for Exit When a REX device Paradoor 460 installed above an Access Control door within a protected area detects movement it sends a signal to the...

Страница 42: ...onjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing...

Страница 43: ......

Страница 44: ...PRINTED IN CANADA 04 2002 DGP2641 EI07...

Отзывы: