24 Reference & Installation Manual
6.2.1 R
EADER
’
S
LED T
O
F
OLLOW
P
ARTITION
’
S
S
TATUS
S
ECTION
[003]: O
PTION
[6]
The reader's LED can be programmed to flash according to
the partition's status. When this feature is enabled, the
reader’s red LED will flash when the partition is arming, in Exit
Delay, in Entry Delay, in Burglar Alarm or in Fire Alarm.
Option [6] OFF= The reader's LED will not flash.
Option [6] ON = LED follows the door’s partition status
(default).
6.2.2 R
EADER
’
S
B
EEP
T
O
F
OLLOW
P
ARTITION
'
S
S
TATUS
S
ECTION
[003]: O
PTION
[7]
This feature will only function when section [003] option [6] is
enabled. The reader can be programmed to beep according to
its keypad's beep when the partition assigned to the door is
arming, in Exit Delay, in Entry Delay, in Burglar Alarm, or in
Fire Alarm.
Option [7] OFF= The beep will not follow the partition's status.
Option [7] ON = Beep follows the partition's status (default).
6.2.3 R
EADER
F
EEDBACK
S
ECTION
[005]: O
PTION
[8]
The reader can be programmed to give visual feedback only
(the reader’s LED flashing) or both visual and audible
feedback (the reader will flash and beep).
Option [8] OFF= The reader’s feedback is visual only (default).
Option [8] ON = The reader’s feedback is both visual &
audible.
Содержание DGP2-641
Страница 1: ...LCD Access Control LCD Keypad V1 0 DGP2 641 DGP2 641AC Reference and Installation Manual...
Страница 10: ...8 Reference Installation Manual Figure 1 Connecting the Keypad and Keypad Zone...
Страница 12: ...10 Reference Installation Manual Figure 4 Access Control Connections DGP2 641AC...
Страница 13: ...Digiplex DigiplexNE LCD Keypad 11n Figure 5 Connecting a Shielded Routing Cable...
Страница 38: ...36 Reference Installation Manual Table 2 Special Characters Catalog...
Страница 43: ......
Страница 44: ...PRINTED IN CANADA 04 2002 DGP2641 EI07...