38 Reference & Installation Manual
in the Event Buffer and can be reported to a
Monitoring Station.
Door Left Open:
Each Access Control door is programmed with a
period of time it is allowed to remain open. Once
the door has been open past this time limit, an
Access Alarm will be triggered (see Access
Alarm).
Event Buffer:
The user-initiated actions, alarms, and troubles
that occur in the system are saved in the control
panel’s memory: the Event Buffer. To view the
events you must enter the Event Record Display
(see Digiplex or DigiplexNE Reference &
Installation Manual). The Access Control events,
however, can only be viewed through an Access
Control Keypad (DGP2-641AC).
Forced Door:
If a protected door was opened without an
“Access Granted” or “Request for Exit” signal, a
silent or audible Access Alarm can be triggered.
If the Access Alarm is programmed to be
audible, the reader assigned to the door can
beep. This event is logged in the Event Buffer,
but can only be seen through an Access Control
keypad (DGP2-641AC) and cannot be reported
to a Monitoring Station unless the door is also
assigned to a zone. If the door is assigned to a
zone, the Forced Door can also trigger a Burglar
Alarm in the system.
Содержание DGP2-641
Страница 1: ...LCD Access Control LCD Keypad V1 0 DGP2 641 DGP2 641AC Reference and Installation Manual...
Страница 10: ...8 Reference Installation Manual Figure 1 Connecting the Keypad and Keypad Zone...
Страница 12: ...10 Reference Installation Manual Figure 4 Access Control Connections DGP2 641AC...
Страница 13: ...Digiplex DigiplexNE LCD Keypad 11n Figure 5 Connecting a Shielded Routing Cable...
Страница 38: ...36 Reference Installation Manual Table 2 Special Characters Catalog...
Страница 43: ......
Страница 44: ...PRINTED IN CANADA 04 2002 DGP2641 EI07...