28 Reference & Installation Manual
schedule started at 7AM, the door remained locked from 7AM
to 8AM. Once access was granted at 8AM, the door remained
unlocked until 5PM.
Option [1] OFF= The Schedule activates without Card (default).
Option [1] ON = Card activates Door Unlocked Schedule.
6.4 DOOR LEFT OPEN OPTIONS
The Door Left Open Options allow you to program how the system
will react to an Access Control door left open.
6.4.1 D
OOR
L
EFT
O
PEN
A
CCESS
A
LARM
S
ECTION
[006]: O
PTION
[2]
When an Access Control door is opened after an Access
Granted or a Request for Exit, an Access Alarm can be
generated if it not closed within a certain period of time (see
section 6.4.2 on page 29).
Option [2] OFF= Door Left Open Alarm will not be generated
(default).
Option [2] ON = Door Left Open Alarm is enabled.
When the Door Left Open Alarm is disabled, the following
sections are also disabled:
Section
[004] Option
[3] Door Left Open Pre-alarm
Option [5] Door Left Open Alarm
Option [6] Door Left Open Alarm follows
[010]
Door Left Open Interval
[011]
Door Left Open Pre-alarm Timer
[012]
Beep Timer for Door Left Open Alarm
Содержание DGP2-641
Страница 1: ...LCD Access Control LCD Keypad V1 0 DGP2 641 DGP2 641AC Reference and Installation Manual...
Страница 10: ...8 Reference Installation Manual Figure 1 Connecting the Keypad and Keypad Zone...
Страница 12: ...10 Reference Installation Manual Figure 4 Access Control Connections DGP2 641AC...
Страница 13: ...Digiplex DigiplexNE LCD Keypad 11n Figure 5 Connecting a Shielded Routing Cable...
Страница 38: ...36 Reference Installation Manual Table 2 Special Characters Catalog...
Страница 43: ......
Страница 44: ...PRINTED IN CANADA 04 2002 DGP2641 EI07...