13. Cable Diagnostics Commands
115
Zxxx0:admin# cable_diag ports 1:1-1:10,1:21
Command: cable_diag ports 1:1-1:10,1:21
Perform Cable Diagnostics ...
Port Type Link Status Test Result Cable Length (M)
------ ---------- ------------- ---------------------------- ------------
1:1 1000BASE-T Link Up OK 65
1:2 1000BASE-T Link Up OK -
1:3 1000BASE-T Link Down Shutdown 25
1:4 1000BASE-T Link Down Shutdown -
1:5 1000BASE-T Link Down Unknown -
1:6 1000BASE-T Link Down Pair 1 Crosstalk at 30M -
Pair 2 Crosstalk at 30M
Pair 3 OK at 110M
Pair 4 OK at 110M
1:7 1000BASE-T Link Down NO Cable -
1:8 1000BASE-T Link Down Pair 1 Open at 16M -
Pair 2 Open at 16M
Pair 3 OK at 50M
Pair 4 OK at 50M
1:9 1000BASE-T Link Down Pair 1 Short at 5M -
Pair 2 Short at 5M
Pair 3 OK at 110M
Pair 4 OK at 110M
1:10 1000BASE-T Link Down Pair 1 Unknown -
Pair 2 Short at 5M
Pair 3 OK at 110M
Pair 4 OK at 110M
1:21 1000BASE-X Link Up Unknown -
Zxxx0:admin#
Содержание ZEQUO 2200
Страница 3: ...3 ...
Страница 86: ...7 ARP Commands 86 ...
Страница 93: ...9 Auto Configuration Commands 93 ...
Страница 273: ...30 IPv6 NDP Commands 273 ...
Страница 330: ...36 LLDP Commands 330 ...
Страница 361: ...39 MAC based Access Control Commands 361 ...
Страница 435: ...45 Network Monitoring Commands 435 Zxxx0 admin clear attack_log Command clear attack_log Success Zxxx0 admin ...
Страница 461: ...49 Protocol VLAN Commands 461 ...
Страница 483: ...50 QoS Commands 483 ...
Страница 504: ...53 SNMPv1 v2 v3 Commands 504 Only Administrator level users can issue this command ...
Страница 523: ...53 SNMPv1 v2 v3 Commands 523 ...
Страница 562: ...57 Subnet VLAN Commands 562 ...