17. Didital Diagnostic Monitoring (DDM) Commands
132
17.Didital Diagnostic Monitoring (DDM)
Commands
17.1. config ddm ports
temperature_threshold
Description
This command is used to configure the thresholds of temperature of the specified ports.
The command configures the temperature thresholds of the specified ports. The precision
of the effective threshold is dependent on the hardware.
Format
config ddm ports [<portlist> | all] temperature_threshold { high_alarm <degrees> |
low_alarm < degrees > | high_warning < degrees > | low_warning < degrees > } (1)
Parameters
config ddm ports [ <portlist> | all ] [[temperature_threshold{ high_alarm <degrees> | low_alarm
<degrees> | high_warning <degrees> | low_warning <degrees>}|voltage_threshold{
high_alarm <voltage> | low_alarm <voltage> | high_warning <voltage> |
low_warning<voltage>} | bias_current_threshold { high_alarm <milliampere> | low_alarm
<milliampere> | high_warning <milliampere> | low_warning<milliampere>} |
tx_power_threshold{ high_alarm <mw_or_dbm> | low_alarm <mw_or_dbm> |
high_warning <mw_or_dbm> | low_warning<mw_or_dbm>} | rx_power_threshold{
high_alarm <mw_or_dbm> | low_alarm <mw_or_dbm> | high_warning <mw_or_dbm> |
low_warning <mw_or_dbm>}] | {state [enable|disable] | shutdown [alarm | warning |
none]}]
config ddm [trap | log] [enable|disable]
config ddm power_unit [mw|dbm]
show ddm
show ddm ports {<portlist>} [status|configuration]
ports
<portlist>
Specifies a range of ports to be configured. (The portlist format: UnitID: port
number).
all
If 'all' parameter is chosen, all optic ports' operating parameters will be configured.
temperature_threshold
Specifies the threshold of the optic module's temperature in centigrade. At least one
parameter shall be specified for this threshold.
Содержание ZEQUO 2200
Страница 3: ...3 ...
Страница 86: ...7 ARP Commands 86 ...
Страница 93: ...9 Auto Configuration Commands 93 ...
Страница 273: ...30 IPv6 NDP Commands 273 ...
Страница 330: ...36 LLDP Commands 330 ...
Страница 361: ...39 MAC based Access Control Commands 361 ...
Страница 435: ...45 Network Monitoring Commands 435 Zxxx0 admin clear attack_log Command clear attack_log Success Zxxx0 admin ...
Страница 461: ...49 Protocol VLAN Commands 461 ...
Страница 483: ...50 QoS Commands 483 ...
Страница 504: ...53 SNMPv1 v2 v3 Commands 504 Only Administrator level users can issue this command ...
Страница 523: ...53 SNMPv1 v2 v3 Commands 523 ...
Страница 562: ...57 Subnet VLAN Commands 562 ...