2. Specifications
WMD078TE0PAA07
9
Note
About EMC classification (Class A)
•
This Class A equipment is not intended for use in residential locations where the electrical power is
provided by the public low-voltage supply system. There can be potential difficulties in ensuring
electromagnetic compatibility in those locations, due to conducted as well as radiated radio-
frequency disturbances.
•
Provided that the public low voltage system impedance at the point of common coupling is lower
than 130 m-ohm and the short circuit power is higher than 6 MVA, this equipment is compliant with
IEC 61000-3-11 and IEC 61000-3-12 and can be connected to public low voltage systems. It is the
responsibility of the installer or user of the equipment to ensure, by consultation with the distribution
network operator if necessary, that the system impedance complies with the impedance restrictions.
2.2 Standard accessories
2.3 Dimensional drawings
Part name
Part number
Qty
Remarks
Glass tube fuse
BET6.3A
1
Safety part, 6.3A, For motor on front panel
BET3.15A
1
Safety part, 3.15A, For volt detect on rear panel.
(Unit: mm)