8. Various settings
WMD078TE0PAA07
79
8.2.2 Setting procedure (WELD NAVI.)
To quit the setting in the middle
Press mode SELECT button to return to the
beginning of the current Mode settings.
1
.
Set material, wire diameter and gas. (See section “
7.1.2 Specifying welding conditions
(material/wire diameter/gas and pulse)
” on page
63.)
2
.
Select WELD NAVI. mode
Press mode SELECT button
several times until LED for WELD
NAVI. is lit.
→
Setting item is indicated on the
first line of LCD.
(The first item “JOINT SELECT”)
→
Set value of the setting item is
indicated on Display2.
Contents of the set value is
indicated on the second line of
LCD.
mode SELECT button
Panasonic
VP1 series
Dial1
Dial2
ENTER button
Display1
Display2
LCD
Display1
Display2
Selected set value
Not in use
JOINT SELECT
- > 1.FILLET?
LCD
Contents of the set
WELD NAVI. setting
item
value (on Display2) of
the setting item