8. Various settings
WMD078TE0PAA07
98
W
eld
in
g v
olt
ag
e u
pp
er
/lo
w
er
lim
it d
et
ec
tio
n
Contact output at
Welding voltage upper
limit detection
34
WELD(V) DET CONTACT
0: OFF
1: ON
-
0
Motion at Welding volt-
age upper limit detec-
tion
35
WELD(V) DET MOVE
0: Continue (Indica-
tion only)
1: Stop at the end
of the current
welding. Then
press ENTER but-
ton to reset.
-
0
<Motion flow>
At motor current upper limit detection and welding current/voltage upper/lower limit detection
①
It detects when cur-
rent/voltage of each
monitoring item goes
beyond/below the
detection value.
②
After the end of detec-
tion time, LCD back-
light blinks.
If the contact output is
set to valid, the jig ter-
minal contact closes.
(See section “
” on page
44.)
W
eld
in
g c
ou
nt
er
Counting the number
of welding ON/OFF
40
WELD COUNTER
0: OFF
1: ON
-
0
Check/reset welding
counter
41
WELD COUNT CHECK
0: Check
1: Reset welding
counter (The ini-
tial screen of
MANAGEMENT
setting dialog
box is displayed.)
-
0
Welding counter target
value
42
TGT WELD COUNT
1 to 30 000
1
30 000
Contents
Sub-
menu
No.
LCD display (1st line)
Setting range
Incre-
ment
Default
Output management function
Preset detection time
Time that exceeds
Upper detection value
Time that exceeds
3 seconds after
Display period on LCD (Blinking)
the detection value
the end of detection
the detection value
Time that falls below
Lower detection value
Display period on LCD (Blinking)
Time that falls below
the detection value
the detection value.
Preset detection time
3 seconds after
the end of detection