7. Welding operation
WMD078TE0PAA07
64
Determine the use of PULSE
Select whether to use PULSE or not.
→
If PULSE is set to valid, the LED above
the button lights solidly.
If the selected welding condition is not
pulse applicable type, the button is
disabled and the LED above the button
stays OFF state.
Pressing PULSE button alternately
switches valid and invalid of PULSE.
●
If a weld table for the selected material, wire diameter and gas exists.
→
The LEDs of the selected items turns
solid.
●
If a weld table for the selected material, wire diameter and gas does no exist.
→
All 3 LEDs remains blinking.
→
LCD shows the message “THERE IS NO
WELDING DATA”.
→
Displays1&2 on the operation box
show “
-
ーー
” and the following opera
-
tions are disabled.
・
Welding output,
・
Receiving torch switch (TS)
・
Inching, and
・
Gas check
Select different welding conditions (mate-
rial, wire diameter and gas type).
●
Changed welding conditions but still cannot find corresponding welding table.
Check if wire extension length is correct.
LED lights solidly,
while PULSE is valid
All 3 LEDs blink
(No indication)
All 3 LEDs blink
THERE IS NO
WELDING DATA
Display1
Display2
LCD
THERE IS NO
WELDING DATA