8. Various settings
WMD078TE0PAA07
96
Contents
Sub-
menu
No.
LCD display (1st line)
Setting range
Incre-
ment
Default
Output management function
M
ot
or
c
ur
re
nt
u
pp
er
lim
it d
et
ec
tio
n
Motor current upper
limit detection ON/OFF
10
MTR(A) MONITOR
0: OFF
1: ON
-
0
Motor current upper
limit detection time (s)
11
MTR(A) DETECT T
0.1 to 99.9
0.1
1.0
Motor current upper
limit set value (A)
12
MTR(A) UP-LIMIT
1.0 to 5.0
0.1
3.0
Contact output at
motor current upper
limit detection ON/OFF
13
MTR(A) MON CONTACT
0: OFF
1: ON
-
0
Motion at motor cur-
rent upper limit detec-
tion
14
MTR(A) DET MOVE
0: Continue (Indica-
tion only)
1: Stop at the end
of the current
welding. Then
press ENTER but-
ton to reset.
-
0
W
eld
in
g c
ur
re
nt
u
pp
er
/lo
w
er
lim
it d
et
ec
tio
n
Welding current upper/
lower limit detection
ON/OFF
20
WELD(A) MONITOR
0: OFF
1: ON
-
0
Welding current upper/
lower limit detection
time (s)
21
WELD(A) DETECT T
0.1 to 99.9
0.1
1.0
Welding current upper
limit set value (%)
Note
Upper limit=Preset
value + (Preset value x
Adjustment value)
Eg.)Preset value: 100 A,
Adjustment value: 10 %
⇒
Upper limit = 110 A
22
WELD(A) UP-LIMIT
0 to 100
1
0
Panasonic
VP1 series
Dial1
Dial2
ENTER button
Indicates set value
Submenu number
・
Use Dial1 to select.
・
Press ENTER to set.
Set value
・
Use Dial2 to select.
・
Press ENTER to set.