8. Various settings
WMD078TE0PAA07
100
Fa
n r
ot
at
io
n t
im
e
Fan rotation time ON/
OFF
70
FAN ROT-T
0: OFF
1: ON
-
0
Check/reset fan rota-
tion time
Note
•
Count up to 9 999 h
59 min 59 s.
Fan rotation time
beyond that amount
won’t be counted.
The counter won’t be
reset to zero (0) auto-
matically.
• Select “1.Reset” to
return to the initial
screen of the MAN-
AGEMENT group.
71
FAN ROT-T CHECK
0: Check
1: Reset the fan
rotation time
-
0
Fan rotation time target
time (h)
72
TARGET FAN ROT-T
1 to 9 999
1
9 999
(*)
: About wire usage:
•
Wire usage is calculated based on wire diameter, wire feed amount (length) per minute, actual
wire feed time and specific gravity of wire. As the specific gravity of wire varies with wire type, for
example, solid wire and flux-cored wire have different specify gravity, which are 7.8
g/cm
3
and
6.5
g/
cm
3
respectively, wire usage may vary with applied wire type.
•
Wire usage is counted in inching operation but not counted in wire retract operation.
Contents
Sub-
menu
No.
LCD display (1st line)
Setting range
Incre-
ment
Default
Output management function
<Motion flow>
When the counter reaches the target value of Welding count, Arc time, wire usage, and fan rotation
time
①
Any one of the monitoring items exceeds
the target value.
②
LCD backlight blinks
.
③
- Reset the monitoring item that has
reached the target value to stop blink-
ing.
- For welding count and accumulated arc
time, press any button to stop blinking.
(Use it as a target for workload)
- For wire usage and fan rotation time,
pressing any button does not stop blink-
ing backlight of LCD. It is to ensure a
steady implementation of maintenance
work.
- Make sure to reset the monitoring item
that has reached the target value, other-
wise, LCD backlight blinks the next time
the item is counted.
Time that exceeds the target value
Target
(LCD blinks)
Reset
value