8. Various settings
WMD078TE0PAA07
126
8.10.5 DIRECT
A function that allows you to perform simple set-
tings by allocating specific setting items, such as
frequently used setting items, to its submenus.
Setting items that can be allocated to DIRECT
(* Submenu numbers no in use are ignored.)
Submenu #
Setting item
Setting range
Increment
Default
DETAIL mode
“Weld parameter”
0
RUN-IN SPEED
-50 to 50
1
0
1
HOT VOLTAGE
-50 to 50
1
0
2
FTT LEVEL
-99 to 99
1
0
3
BURNBACK TIME
-99 to 99
1
0
4
PENETRATION
-30 to 30
1
0
5
PRE-FLOW TIME
0.0 to 10.0
0.1
0.2
6
POST-FLOW TIME
0.0 to 10.0
0.1
0.5
7
PULSE PEAK CUR
-99 to 99
1
0
8
PULSE BASE CUR
-99 to 99
1
0
9
PULSE RISE CUR
-30 to 30
1
0
10
PULSE FALL CUR
-30 to 30
1
0
11
WFS FINE ADJ
(*1)
-50 to 50
1
0
13
WAVE CONTROL 1
-99 to 99
1
0
14
PULSE FREQ
(*2)
-99 to 99
1
0
17
PULSE WIDTH
-99 to 99
1
0
18
CRATER DC
0: Invalid
1: Valid
-
0
19
INIT PLS DC
0: Invalid
1: Valid
-
0
20
LOW PULSE SET
0: Invalid
1: Valid
2: Automatic
(*3)
-
0
21
LOW PULSE CUR
30 to 400
2
120
22
LOW PULSE VOL
5 to 50
0.2
20.2
23
LOW PULSE FREQ
0.5 to 10
0.1
2.0
24
LOW PULSE DUTY
10 to 90
5
50
25
LOW PULSE DELAY
0 to 9.9
0.1
0
30
DISPLAY TIME
1 to 30
1
5
32
PENET INC
0: Invalid
1: Valid
2: Automatic
-
2
(*1)
The same setting item as “WIRE-FEED ADJUST” in
SET button.
(*2)
Not adjustable if material is set to either “AL-HARD (
Hard aluminum
)” or “AL-SOFT (
Soft aluminum
)”.
(*3)
Not adjustable if “2: AUtomatic” is selected ” as “LOW PULSE DELAY” in this setting becomes “0”.