The gas icon will turn off after approximately
3 minutes, and the area around the MENU
button will flash in red.
●
Once gas is no longer detected, the alarm
stops. Also, the GAS indicator, area around the
MENU button, ALARM indicator on the call
sub-base unit, and door phone alarm display
indicator turn off.
●
The GAS indicator appears only on the base
unit.
●
The area around the MENU button, GAS
indicator, ALARM indicator, and alarm display
indicator continue to flash until there is no more
gas in the gas detector.
●
The gas icon can also be turned off within
3 minutes. ( Page 155)
●
The detector disconnected icon will turn off
after approximately 1 minute, and the area
around the MENU button will flash in red.
●
Once the detector wiring is reconnected,
the alarm stops. Also, the area around the
MENU button, FIRE indicator, and door
phone alarm display indicator turn off.
●
After pressing the STOP ALARM button,
touching on the base unit will cause
the screen to return to the waiting state, and
the area around the MENU button will light
up in red. To display the detector
disconnected icon, touch on the Top
Menu screen. ( Pages 20 to 21)
●
The FIRE indicator continues to appear, the
area around the MENU button continues to
light up or flash, and the alarm display
indicator continues to flash until the detector
wiring is reconnected.
●
The detector disconnected icon can also be
turned off within 1 minute. ( Page 155)
160
161
When the gas detector detects gas, the system
reports a gas leak.
In the Event of Detector Disconnection
In the Event of a Gas Leak
In the Event of Fire or Disconnection
In the Event of a Gas Leak or Disconnection
Confirm that system components are properly installed before using the system.
STOP ALARM
button
FIRE
indicator
appears
in red
Door phone
Alarm display indicator
Flashes in red
Alarm is sounding
When detector wiring becomes disconnected,
the system reports a disconnection.
●
Press the STOP ALARM button.
(The alarm can also be turned off from
the building manager room.)
●
The alarm can be disabled.
How to stop the alarm sound
Procedures during alarms
(Beeps)
Detector
disconnected
icon appears
in red
MENU button
Call sub-base unit
Alarm is sounding
Cautions
●
Shut off the main gas valve and open
the windows and doors to ventilate the room.
How to stop the alarm sound
Procedures during alarms
STOP ALARM
button
Gas icon
flashes in yellow
GAS
indicator
flashes
in yellow
GAS indicator
flashes in yellow
Door phone
Alarm display indicator
Flashes in red
Alarm is sounding
(Rapid beeps)
Gas leak.
After approx.
40 seconds
MENU
button
Call sub-base unit
ALARM indicator
Flashes in red
Alarm is sounding
The gas detector
detects a gas leak
Appears in white
MENU button
Consult with the management
company or the company that
installed the system.
Gas icon
flashes in yellow
Confirm button
●
Press the STOP ALARM button on the base
unit. Note that the gas detector alarm will
not turn off.
Pressing the STOP ALARM button on
the call sub-base unit with monitor does
not stop the alarms on other equipment.
●
Exposure to moisture containing alcohol from
cooking sauces and wines, etc. may cause
the gas detector to generate false
detections.
The system can be configured to
trigger the gas leak alarm as the gas
detector activates.
Consult with the management
company or the company that
installed the system.
Note
Note
Note
Note
INTRODUCTION
USUAL USAGE
SETTING ACCORDING TO
YOUR PREFERENCES
OPERATIONS AND MEASURES
WHEN ALARM GOES OFF
SECURITY ALARM SETTING
AND DISARMING
RECORD
MANAGEMENT
OTHER
Installer
Setting
Installer
Setting
●
For base unit
●
For base unit
●
For base unit
●
For call sub-base unit with monitor
and do not appear in the call
sub-base unit with monitor