76
For optional pump.
Power supply: AC230V/50Hz, <500W
Recommended part: Yonos 25/6: made by Wilo
For optional mixing valve.
Power supply: AC230V/50Hz (input open/output
close)
Operating time: 30s~120s
Recommended part: 167032: made by Caleffi
WARNING
This section is for authorized and licensed electrician/water system
installer only. Work behind the front plate secured by screws must
only be carried out under supervision of qualified contractor,
installation engineer or service person.
11.2.3.6 Network
Adaptor
8
Installation
(Optional)
1.
Open the Control Board Cover
6
, then
connect the cable included with this adaptor to
the CN-CNT connector on the printed circuit
board.
Pull the cable out of the Indoor Unit so that there
is no pinching.
If an optional PCB has been install in the Indoor
Unit, connect the CN-CNT connector to Optional
PCB
7
.
Connection examples: H series
CN-CNT cable
For S*C09*3E8
For S*C12/16*9E8
Without Optional PCB
CN-CNT cable
For S*C09*3E8
For S*C12/16*9E8
With Optional PCB
2.
Insert a flat head screwdriver into the slot on
the top of the adaptor and remove the cover.
Connect the other end of the CN-CNT cable
connector to the connector inside the adaptor.
Slot
Connector
3.
On the wall near the Indoor Unit, attach the
adaptor by screwing screws through the holes
in the back cover.
Screws
4.
Pull the CN-CNT cable through the hole in the
bottom of the adaptor and re-attach the front
cover to the back cover.
CN-CNT cable
(Take care not to
pinch the cable)