161
Operational
Control
Direction
Displays the operation status of controlled direction by IEEE 802.1X
function.
Both
Unless the client is authenticated, this Switching Hub does
not send or receive packets from the port.
In
Unless the client is authenticated, this Switching Hub does
not receive packets from the port.
Administrative
Control
Direction
Displays the administrative status of controlled direction by IEEE
802.1X function.
Both
Unless the client is authenticated, this Switching Hub does
not send or receive packets from the port.
In
Unless the client is authenticated, this Switching Hub does
not receive packets from the port.
Per Port Re-auth Displays whether the periodic re-authentication is enabled or disabled.
Enabled
The periodic re-authentication is performed.
Disabled
The periodic re-authentication is not performed. (Factory
default setting)
Current PVID
Displays a current allocated PVID.
Dynamic VLAN
Displays the dynamic VLAN operation status.
Disabled
The dynamic VLAN function is disabled.
<VLAN ID> The dynamic VLAN function is enabled, and displays the
allocated VLAN ID.
Guest Access
Mode
Displays the Guest Access application conditions.
Timeout
Guest Access is applied when a Supplicant Timeout
occurs.
Auth Fail
Guest Access is applied when authentication fails.
Both
Guest Access is applied when either the Timeout or Auth
Fail condition is matched.
Transmit Period The number of seconds to wait before requesting the client to
reattempt authentication. The factory default setting is 30 seconds.
Max Request
The maximum number of times of retransmitting an authentication
request. The factory default setting is 2 times.
Supplicant
Timeout
Displays the timeout for the client. The factory default setting is 30
seconds.
Quiet Period
The number of seconds to wait before reattempting a failed
authentication The factory default setting is 60 seconds.
Serv Timeout
Timeout for the authentication server The factory default setting is 30
seconds.
Re-auth Period Periodic re-authentication time interval The factory default setting is
3600 seconds.
Guest VLAN ID
Displays the VLAN ID applied to Guest Access. When Guest Access is
disabled, the field displays "----."
Default VLAN ID Displays the VLAN ID applied when the Port Control setting is changed
from Auto to Force Authorized or Force Unauthorized. The default
VLAN ID is also applied when VLAN information cannot be obtained
from the authentication server although the dynamic VLAN is enabled
and the authentication succeeded.
Содержание Switch-M12PWR
Страница 6: ...6 malfunction When stacking Switching Hubs leave a minimum of 20 mm space between them is required ...
Страница 17: ...17 Fig 2 2 Mounting to Wall ...
Страница 20: ...20 function does not work Therefore use a cross cable to connect them ...
Страница 28: ...28 command If you enter a command or setting not available an error message is shown in the explanation field ...
Страница 30: ...30 ...
Страница 36: ...36 ...
Страница 49: ...49 ...
Страница 69: ...69 ...
Страница 78: ...78 Quit to previous menu Quits the Advanced Switch Configuration Menu and returns to the Main menu ...
Страница 81: ...81 setting and the management VLAN status of VLAN ID 1 is UP ...
Страница 96: ...96 Press S Q Return to the previous menu ...
Страница 98: ...98 ...
Страница 122: ...122 Q Return to the previous menu ...
Страница 125: ...125 ...
Страница 130: ...130 ICMP Type Displays the ICMP type ...
Страница 136: ...136 802 1p Priority Displays priority of IEEE802 1p TCP SYN Flag Displays the TCP SYN flag ICMP Type Displays ICMP type ...
Страница 156: ...156 Threshold Displays the threshold of the number of packets per second ...
Страница 173: ...173 Fig 4 7 49 Display of values accumulated after resetting the counters ...
Страница 185: ...185 Q Return to the previous menu ...
Страница 211: ...211 Q Return to the previous menu ...
Страница 232: ...232 IEEE8021 PAE MIB IEEE802 1X IEEE8023 LAG MIB IEEE 802 3ad ...
Страница 237: ...237 IEEE 802 3af standard ...
Страница 240: ...240 P0813 1084 ...