ENABLE/DISABLE
Operation for all channels is not accepted when set to “Disable”.
Performance
Parameter
Default value
Disable
0-127
0
Enable
128-255
Note
f
If the projector is operated using the remote control or the control panel, or by the control command while controlling the projector using the
Art‑Net function, the setting of the DMX controller or computer application may be different from the projector status. To reflect the controls
of all channels to the projector, set “ENABLE/DISABLE” of channel 11 to “Disable” and then back to “Enable”.
f
To create and register the USER LOGO image, use “Logo Transfer Software”. The software can be downloaded from the Panasonic website
(https://panasonic.net/cns/projector/).
Control commands via LAN
The projector can be controlled via the <DIGITAL LINK/LAN> terminal by using the control command format via
the <SERIAL IN> terminal.
For examples of the available commands, refer to “Control command” (
x
page 247).
Note
f
To send/receive the command via LAN, it is necessary to set the password of the administrator account. (
x
page 190)
Connecting
1) Obtain the IP address and port number (Initial set value = 1024) of the projector and request a
connection to the projector.
f
You can obtain both the IP address and the port number from the menu screen of the projector.
IP address
Obtain from the [NETWORK] menu
→
[NETWORK STATUS].
Port number
Obtain from the [NETWORK] menu
→
[NETWORK CONTROL]
→
[COMMAND PORT].
2) Check the response from the projector.
Data section
Blank
Mode
Blank
Random number section
Termination
symbol
Command
example
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘1’
0x31
‘ ’
0x20
“zzzzzzzz”
(ASCII code hex number)
(CR)
0x0d
Data length
9 bytes
1 byte
1 byte
1 byte
8 bytes
1 byte
f
Mode: 1 = Protect mode
f
Example: Response during protect mode (random number section is undefined value)
“NTCONTROL 1 23181e1e” (CR)
3) Generate a 32-byte hash value from the following data using MD5 algorithm.
f
“xxxxxx:yyyyy:zzzzzzzz”
xxxxxx
The user name for the administrator account
yyyyy
The password for the administrator account
zzzzzzzz
8-byte random number obtained in Step
2)
Command transmission method
Transmit using the following command formats.
r
Transmitted data
Header
Data section
Termination
symbol
Command
example
Hash value
“Connecting” (
x
page 242)
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length
32 bytes
1 byte
1 byte
Undefined length
1 byte
Содержание PT-RZ16K
Страница 58: ...58 ENGLISH Chapter 3 Basic Operations This chapter describes basic operations to start with...
Страница 196: ...196 ENGLISH Chapter 5 Operations This chapter describes how to use each function...
Страница 234: ...234 ENGLISH Chapter 7 Appendix This chapter describes specifications and after sales service for the projector...