How to replace a Kestrel Series circuit board 

 
 
 

   

 
 

 

 

1. Raise the screen about 2 feet, 

and then unplug the power cord. 

 

VERY  IMPORTANT: 

Use  rope  to 

tie  the  screen  from  both  ends 

after  raising  it.  When  removing 

the  end  cap,  the  screen  will 

spring  open  and  can  cause 

serious 

injury 

and 

can 

permanently damage the screen.

   

2.  REMOVE  the  6  screws  as 

shown  on  the  picture  marked 

in red. 

Summary of Contents for Kestrel Series

Page 1: ...n about 2 feet and then unplug the power cord VERY IMPORTANT Use rope to tie the screen from both ends after raising it When removing the end cap the screen will spring open and can cause serious injury and can permanently damage the screen 2 REMOVE the 6 screws as shown on the picture marked in red ...

Page 2: ...avoid pulling out the motor 5 Push the cover to the side to remove it 4 After removing the end cap cover you will notice a metal box directly behind the screen s material This metal box houses the circuit board Loosen and remove the screws that hold the cover of this metal box ...

Page 3: ...out of the way 8 Detach indicated wires from the circuit and remove the small screws that hold it in place Then remove the circuit board Do the reverse of step 8 instructions to replace the new circuit board 7 To open the circuit board box cover push in on the tab as shown in the picture and pull the box open with both hands simultaneously ...

Page 4: ...Rev111010 ESC www elitescreens com 9 Put the circuit box cover back in to place 10 Place the circuit box back in to place 11 Use the included screw to guide the metal cover back in to place ...

Page 5: ...2 Put metal box cover back in to place and tighten with the screw and nut 13 For easier access place a small platform like a piece of Styrofoam under the screen so that it is elevated about a few inches Check to be sure that the limit switches are facing the right direction as shown in this picture and that the wires are snugly put back in to the screen s casing so that the end cap cover can be ea...

Page 6: ...tely sealing the end cap back in to place 16 Put the end cap back in to place and tighten the end cap with the provided screws as shown in the picture 17 Check for any loose wires that may be sticking out of the casing The slit for the screen should be clear for a smooth deployment of the material ...

Page 7: ...Rev111010 ESC www elitescreens com 18 If in case the end cap does not seal properly check to be sure that the limit switch cap is fully inserted in to the roller ...