301
[Supplement]
Supplement
command
9
mode
1
• Individual Read out of Alarm History
Reception data
1
axis
history No.
checksum
9
1
Error code
Transmission data
• History No. 1 to 14 represents latest to 14th latest error event.
• No. error will occur when you enter other value than 1 to 14.
bit7
0 : Normal
1 : Error
6
5
4
3
No.Error
2
1
0
3
axis
history No.
alarm No.
error code
checksum
9
1
command
9
mode
2
• Batch Read out of Alarm History
Reception data
0
axis
checksum
9
2
Error code
Transmission data
• You can read out last 14 error events.
bit7
0 : Normal
1 : Error
6
5
4
3
2
1
0
0Fh
axis
alarm No.
alarm No.
–
alarm No.
Error code
checksum
9
2
command
9
mode
0
• Read out of Present Alarm Data
Reception data
0
axis
checksum
9
0
Error code
Transmission data
• If no alarm occurs, alarm No. becomes 0.
(For alarm No., refer to P.252, "Protective function (What is alarm code ?)" of When in Trouble.
bit7
0 : Normal
1 : Error
6
5
4
3
2
1
0
2
axis
alarm No.
error code
checksum
9
0
Command error RS485 error
Command error Command error
Command error Command error
1st. latest
2nd. latest
14th. latest