17
[Before Using the Products]
Before Using
the Products
Absolute/Incremental Specifications, 17-bit
<Remarks> Do not use in other combinations than those listed below.
Single phase,
200V
3-phase,
200V
Single phase,
100V
Single phase,
200V
Single phase,
100V
Single phase,
200V
Single/3-phase,
200V
3-phase,
200V
Single/3-phase,
200V
3-phase,
200V
Single/3-phase,
200V
3-phase,
200V
Single/3-phase,
200V
3-phase,
200V
Single/3-phase, 200V
3-phase, 200V
MAMA
Ultra low
inertia
MAMA
Low
inertia
MSMD
Low
inertia
MSMA
Low
inertia
MDMA
Middle
inertia
MHMA
High
inertia
MFMA
Middle
inertia
MGMA
Middle
inertia
Power
supply
Motor
series
Applicable motor
Applicable driver
5000r/min
3000r/min
3000r/min
3000r/min
2000r/min
2000r/min
2000r/min
1000r/min
Rated
rotational speed
100W
200W
400W
750W
100W
200W
400W
100W
200W
400W
50W
100W
200W
400W
50W
100W
200W
400W
750W
1.0kW
1.5kW
2.0kW
3.0kW
4.0kW
5.0kW
1.0kW
1.5kW
2.0kW
3.0kW
4.0kW
5.0kW
500W
1.0kW
1.5kW
2.0kW
3.0kW
4.0kW
5.0kW
400W
1.5kW
2.5kW
4.5kW
900W
2.0kW
3.0kW
4.5kW
Rated
output
MAMA012S1*
MAMA022S1*
MAMA042S1*
MAMA082S1*
MQMA011S1*
MQMA021S1*
MQMA041S1*
MQMA012S1*
MQMA022S1*
MQMA042S1*
MSMD5AZS1*
MSMD011S1*
MSMD021S1*
MSMD041S1*
MSMD5AZS1*
MSMD012S1*
MSMD022S1*
MSMD042S1*
MSMD082S1*
MSMA102S1*
MSMA152S1*
MSMA202S1*
MSMA302S1*
MSMA402S1*
MSMA502S1*
MDMA102S1*
MDMA152S1*
MDMA202S1*
MDMA302S1*
MDMA402S1*
MDMA502S1*
MHMA052S1*
MHMA102S1*
MHMA152S1*
MHMA202S1*
MHMA302S1*
MHMA402S1*
MHMA502S1*
MFMA042S1*
MFMA152S1*
MFMA252S1*
MFMA452S1*
MGMA092S1*
MGMA202S1*
MGMA302S1*
MGMA452S1*
Model
A-frame
B-frame
C-frame
D-frame
A-frame
B-frame
C-frame
A-frame
A-frame
B-frame
A-frame
B-frame
C-frame
A-frame
B-frame
C-frame
D-frame
E-frame
F-frame
D-frame
E-frame
F-frame
C-frame
D-frame
E-frame
F-frame
C-frame
D-frame
E-frame
F-frame
D-frame
F-frame
Frame
MADDT1207
MBDDT2210
MCDDT3520
MDDDT5540
MADDT1107
MBDDT2110
MCDDT3120
MADDT1205
MADDT1207
MBDDT2210
MADDT1105
MADDT1107
MBDDT2110
MCDDT3120
MADDT1205
MADDT1207
MBDDT2210
MCDDT3520
MDDDT5540
MEDDT7364
MFDDTA390
MFDDTB3A2
MDDDT3530
MDDDT5540
MEDDT7364
MFDDTA390
MFDDTB3A2
MCDDT3520
MDDDT3530
MDDDT5540
MEDDT7364
MFDDTA390
MFDDTB3A2
MCDDT3520
MDDDT5540
MEDDT7364
MFDDTB3A2
MDDDT5540
MFDDTA390
MFDDTB3A2
Model
<Notes>
1) Suffix of " * " in the applicable motor model represents the motor structure.
2) Default of the driver is set for the incremental encoder specifications.
When you use in absolute, make the following operations.
a) Install a battery for absolute encoder. (refer to P.314, "Options" of Supplement.)
b) Switch the parameter Pr0B (Absolute encoder setup) from "1 (default)" to "0".
3) No wiring for back up battery is required when you use the absolute 17-bit encoder in incremental.
Содержание Minas A4 Series
Страница 307: ...305 Supplement Supplement MEMO ...
Страница 364: ...362 MEMO ...