98
Wiring to the Connector, CN X5
1k
Ω
CW
pulse
command
input
19
20
17
18
7
8
9a
9b
11
12
1
4
5
3
PULS1
PULS2
SIGN1
SIGN2
OZ+
OZ
–
GND
COM+
CL
SRV-ON
GAIN/TC
A-CLR
CCWL
CWL
S-RDY+
S-RDY
–
ALM+
ALM
–
COIN+
COIN
–
COM
–
3
4
5
6
23
24
13
7
30
29
27
31
9
8
35
34
37
36
39
38
41
CCW
pulse
command
input
Counter clear
input
Servo-ON
input
Servo-Ready
output
Servo-Alarm
output
Positioning
complete
output
Alarm clear
input
CW
over-travel
inhibit input
CCW
over-travel
inhibit input
PLC
F3NC11-0N
Driver
A4-series
Z-phase
output
Origin proximity
sensor
CW limit
sensor
CCW limit
sensor
from
PLC I/O
output
to
PLC I/O
input
V
+
GND
CW
pulse command
output
CCW
pulse command
output
Origin line driver
input
3.5k
Ω
Emergency stop
input
Origin proximity
input
CCW limit input
CW limit input
5V power supply
for pulse output
220
Ω
220
Ω
4.7
k
Ω
4.7
k
Ω
4.7
k
Ω
4.7
k
Ω
4.7
k
Ω
4.7
k
Ω
3.5k
Ω
3.5k
Ω
3.5k
Ω
Gain switching/
Torque limit
switching input
GND
+
5V
DC5V
Power supply
GND
+
24V
DC24V
Power supply
Yokogawa Electric , F3NC11-ON
represents twisted pair wire.
<Remark>