102
Wiring to the Connector, CN X5
Omron, C200H-NC211
1.6k
Ω
1.6k
Ω
150
Ω
2k
Ω
2k
Ω
2k
Ω
2k
Ω
220
Ω
220
Ω
4.7
k
Ω
4.7
k
Ω
4.7
k
Ω
4.7
k
Ω
4.7
k
Ω
4.7
k
Ω
Pulse (CW+CCW)
output
CW
pulse
command
input
2
13
9
11
1
23
4
22
19
7
17
18
PULS1
PULS2
SIGN1
SIGN2
OZ+
OZ–
GND
COM+
CL
SRV-ON
GAIN
A-CLR
CCWL
CWL
S-RDY+
S-RDY–
ALM+
ALM–
COIN+
COIN–
COM–
3
4
5
6
23
24
13
7
30
29
27
31
9
8
35
34
37
36
39
38
41
Directional output
CCW
pulse
command
input
Origin line driver
input
Deviation
counter reset output
Power supply
for output
Counter clear
input
Servo-ON
input
Servo-Ready
output
Servo-Alarm
output
Positioning
complete
output
Gain
switching
input
Alarm clear
input
CW
over-travel
inhibit input
CCW
over-travel
inhibit input
Emergency
stop input
PLC
C200H-NC211
Driver
A4-series
Z-phase
output
from
PLC I/O
output
to
PLC I/O
input
Origin proximity
input
CCW limit over
input
CW limit over
input
V+
GND
Origin proximity
sensor
CW limit
sensor
CCW limit
sensor
GND
+
24V
DC24V
Power supply
represents twisted pair wire.
<Remark>