203
[Connection and Setup of Full-closed Control]
Full-Closed
Control Mode
Output Signals (Analog) and Their Functions
Title of signal
Pin No
Symbol
Function
I/F circuit
Torque monitor
signal output
42
AO
P.194
IM
• The content of output signal varies depending on Pr08 (Torque monitor
(IM) selection).
• You can set up the scaling with Pr08 value.
Content of signal
Torque
command
Positional
deviation
Full-closed
deviation
Function
• Feeds out the voltage in proportion to the motor
torque command with polarity.
+ : generates CCW torque
– : generates CW torque
• Feeds out the voltage in proportion to the positional
deviation pulse counts with polarity.
+ : positional command to CCW of motor position
– : positional command to CW of motor position
• Feeds out the voltage in proportion to the full-
closed deviation pulse counts with polarity.
+ : positional command to CCW of
external scale position
– : positional command to CW of
external scale position
Pr08
0,
11,12
1 – 5
6 –10
Speed monitor
signal output
43
AO
P.194
SP
• The content of the output signal varies depending on Pr07 (Speed monitor
(IM) selection).
• You can set up the scaling with Pr07 value.
• Feeds out the voltage in proportion to the motor
speed with polarity. + : rotates to CCW
– : rotates to CW
• Feeds out the voltage in proportion to the command
speed with polarity.
+ : rotates to CCW
– : rotates to CW
Function
Control mode
Pr07
Motor
speed
Command
speed
0 – 4
5 – 9
Output Signals (Others) and Their Functions
Title of signal
Pin No
Symbol
Function
I/F circuit
Signal ground
13,15,
17,25
–
GND
• Signal ground
• This output is insulated from the control signal power (COM–) inside of the
driver.
Frame ground
50
–
FG
• This output is connected to the earth terminal inside of the driver.