RS232C Co
mmunication
11.2 Serial (Per Start)/Serial (Async.)
If "Serial (Per Start)” or “Serial (Async.)“ is used for communication, set a communication method, output
data and format for the output data or receiving a command from the external device. Select
“ENVIRONMENT” > "Output Setting" or "Serial Setting" from the menu bar.
11.2.1 Slecting Outputting Procedure/Data
Selecting outputting setting/data here.
Item
Option
Description
Output
Setting
No/Serial (Per Start)/Computer
Link/Serial (Async.) /Ethernet/Card
Select the output destinations or methods
Output Data: Judgement/Data Monitor/Both
Select output data from Judgement/ Data
Monitor/Both.
Output Digit
0 to 11 (Output Setting: Not available in
Computer Link)
Set the maximum number of digits to output.
Invalid Digit
Delete/Zero (Output setting: Not
available in Computer Link)
If the data are under the number of output
digits, select "Delete/0".
The following items are available only for computer link mode.
Refer to page 241 for further details: PLC Model, Start Register, Timeout and Data Type
11.2.2 Format of the Commands from the External Device
Serial Setting- Specifying the Digit Number of the Items for the Command
Item
Selection
Description
Data Digit: To specify how to segment each item of the commands from the external device
Valid
Insert commas between the items.
Fixed
(4 Digit)
Specify a command with 4 digits. Do not insert a symbol to separate each
items.
Invalid Digit: To determine what is specified as invalid digit if each item of the commands is less than 4
digits when “Fixed (4 Digit)” is specified.
Space
If the digit number of each item is less than 4, the spaces will be allocated
to the invalid numbers.
Zero
If the digit number of each item is less than 4, "0" will be allocated to the
invalid numbers.
Содержание Micro-Imagechecker AX40
Страница 9: ...1 Names and Functions of Parts Chapter 1 Chapter 1 Names and Functions of Parts ...
Страница 15: ...7 Installation and Wiring Chapter 2 Chapter 2 Installation and Wiring ...
Страница 25: ...17 Input and Output Interface Ports Chapter 3 Chapter 3 Input and Output Interface Ports ...
Страница 42: ......
Страница 55: ...47 Chapter 5 Procedure for Setting Inspection Conditions Chapter 5 Procedure for Setting Inspection Conditions ...
Страница 70: ......
Страница 94: ...86 Setting Checkers Chapter 6 6 7 Gray Edge 6 7 1 Menu Options ...
Страница 108: ...100 Setting Checkers Chapter 6 6 9 Smart Matching 6 9 1 Menu Options ...
Страница 184: ......
Страница 185: ...177 TOOL Chapter 8 Chapter 8 TOOL ...
Страница 192: ......
Страница 193: ...185 Environment Settings Chapter 9 Chapter 9 Environment Settings ...
Страница 215: ...207 Chapter 10 Parallel Communication Chapter 10 Parallel Communication ...
Страница 225: ...217 Chapter 11 RS232C Communication Chapter 11 RS232C Communication ...
Страница 255: ...247 Chapter 12 Ethernet Communication Chapter 12 Ethernet Communication ...
Страница 261: ...253 Chapter 13 Using a CF Card Chapter 13 Using a CF Card ...
Страница 273: ...265 Chapter 14 Information on AX40 and Help Function Setting Chapter 14 Information on AX40 and Help Function Setting ...
Страница 279: ...271 Chapter 15 Troubleshooting Chapter 15 Troubleshooting ...
Страница 283: ...275 Chapter 16 Specifications and Product Numbers Chapter 16 Specifications and Product Numbers ...
Страница 291: ...283 Chapter 16 Specifications and Product Numbers 16 3 Dimensions AX40 Random Color Camera Product number ANMX8310 ...
Страница 292: ...284 Specifications and Product Numbers Chapter 16 Camera Cable Keypad ...
Страница 293: ...285 Chapter 16 Specifications and Product Numbers Lens ANB846NL ANB845NL ANB847L ANB843L ANM8850 ANM88501 Unit mm ...
Страница 294: ...286 Specifications and Product Numbers Chapter 16 ANM88161 ANM88251 ANB842NL Unit mm ...
Страница 296: ...288 Record of Changes Manual No Date Description of Changes ARCT1F462E March 2009 First Edition ...