120
3-2-3 Each command description in LP-F10/F10W mode
Reference
•
The laser marker sends a response data after setting/readout command is transmitted.
•
Refer to “2-5 Communication Data Format” (P.28)
■
Command mode setting: RSM
Switches between Standard mode and LP-F10/F10W.
Setting / Readout data of command mode
STX
RSM
Sub
command
[Command mode]
1-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of command mode
STX
RSM
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Command
mode
1
“0”: LP-F10/LP-F10W mode
“1”: Standard mode
Reference
•
This command is valid only when the DIP switches are set to LP-F10 mode or LP-F10W mode.
•
When the Remote mode is set to OFF or power is OFF, the mode returns to the initial value (LP-F10/LP-F10W mode).