162
■
Line speed: LSP
[Supported models: LP-Mxxx/LP-Sxxx/LP-Zxxx]
Sets the line speed in flying object marking (scan speed).
Setting / Readout data of line speed
STX
LSP
Sub
command
[Line speed]
6-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of line speed
STX
LSP
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Line speed
6
“00.060”–“60.000” [m/min]
The speed with which the object to be marked
passes is indicated, available only when the traveling
direction is other than “still” and encoder signal is
“OFF”.
Reference
• The value more than 60.000 cannot be specified. (NAK09 is returned.)
•
When the setting exceeds 60.000 and readout is tried, NAK15 is returned.
■
Encoder signal: ENC
[Supported models: LP-Mxxx/LP-Sxxx/LP-Zxxx]
Sets the encoder pulse value for use of the encoder in flying object marking.
Setting / Readout data of encoder signal
STX
ENC
Sub
command
[Encoder pulse]
6-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of encoder signal
STX
ENC
R
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Encoder pulse
6
“005.00”–“600.00” [Pulse/mm]
Available only when the moving direction is
other than “still”.
Reference
•
The setting changed by this command is saved without overwriting.
ME-LPMSZ-SR-9
Содержание LP-M Series
Страница 8: ...1 Before External Control ME LPMSZ SR 9...
Страница 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Страница 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Страница 165: ...Troubleshooting ME LPMSZ SR 9...
Страница 186: ...Character Code Table ME LPMSZ SR 9...
Страница 199: ...Index ME LPMSZ SR 9...
Страница 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Страница 203: ...No 9000 0063 59V...
Страница 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...