73
■
DXF logo condition: CDD
Sets the marking condition of DXF logo file.
Setting / Readout data of DXF logo condition
STX
CDD
Sub
command
[Logo No.] [Layer No.] [Origin position] [X position] [Y position]
[Rotation angle] [Size specification] [Width] [Height] [Font No.]
[Marking pitch] [Marking direction] [Laser power correction]
[Scan speed correction] [Laser pulse cycle correction]
Max. 60-byte (LP-Mxxx / LP-Sxxx / LP-Zxxx), Max. 57-byte (LP-SxxxW)
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of DXF logo condition
STX
CDD
R
[Logo No.]
2-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Content
Remarks
Logo No.
2
“00”–“99”
Layer No.
2
“00”–“15”
Origin position
1
“0”: Center
“1”: Left bottom
“2”: Right bottom
“3”: Left top
“4”: Right top
“5”: Original graphic
X position
8
“-330.000”–“+330.000” [mm]
Specifies the origin coordinate of the
logo.
Y position
8
Rotation angle
7
“-180.00”–“+180.00” [°]
Size
specification
1
“0”: Height/Width
“1”: Width
“2”: Height (width fixed)
“3”: As original graphic size
Width
(7)
Model type*
Setting range [mm]
LP-Sxx0(W)
“000.100”–“090.000”
LP-Sxx5(W)
“000.100”–“160.000”
LP-Sxx2
“000.100”–“055.000”
LP-Mxx0/LP-Zxx0
“000.100”–“120.000”
LP-Mxx5
“000.100”–“220.000”
LP-Mxx6/LP-Zxx6 “000.100”–“330.000”
Available only “0”: Height/Width
or “1”: Width is specified at “Size
specification”.
Height
(7)
Available only “0”: Height/Width
or “2”: Height is specified at “Size
specification”.
Font No.
2
Char. Font “01”–“10”
Sets font of logo file data.
Marking pitch
5
“0.010”–“2.000”
Marking direction
1
“0”: Lateral, “1”: Longitudinal
Laser power
correction
3
“000”–“999” [%]
•
The correction ratio is calculated
using the value set at the laser
condition as 100%.
•
With LP-SxxxW type, nothing
should be input in Laser Pulse
Cycle Correction.
Scan speed
correction
3
“001”–“999” [%]
(Laser pulse
cycle correction)
(3)
“001”–“999” [%]
* For the detail of the model type, refer to “Target laser marker” (P.4).
ME-LPMSZ-SR-9
Содержание LP-M Series
Страница 8: ...1 Before External Control ME LPMSZ SR 9...
Страница 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Страница 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Страница 165: ...Troubleshooting ME LPMSZ SR 9...
Страница 186: ...Character Code Table ME LPMSZ SR 9...
Страница 199: ...Index ME LPMSZ SR 9...
Страница 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Страница 203: ...No 9000 0063 59V...
Страница 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...