134
■
Expiry date/time condition: LMT
Sets the expiry date/time condition.
Setting / Readout data of expiry date/time condition
Expiry date/time can be set within the range from January 1, 1980 to December 31, 2099.
STX
LMT
Sub
command
[Expiry No.] [Expiry] [Reference unit] [Start date]
6-byte
(Check sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
Readout request of expiry date/time condition
STX
LMT
R
[Expiry No.]
1-byte
(Check sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Expiry No.
1
“1”–“4”
Expiry
3
“001”–“999”
Reference unit
1
•
Expiry (future)
“0”: Year
“1”: Month
“2”: Day
“3”: Hour
“4”: Minute
•
Expiry (past)
“5”: Year
“6”: Month
“7”: Day
“8”: Hour
“9”: Minute
Start date
1
“0”: Today not included
“1”: Today included
Possible to be set only when the reference unit
is set to “year” or “month”. Indicating if the date
of “today” is included or not.
Reference
•
The common expiry (expiry Nos. 5 to 8) cannot be set and read out. (NAK09 is returned.)
ME-LPMSZ-SR-9
Содержание LP-M Series
Страница 8: ...1 Before External Control ME LPMSZ SR 9...
Страница 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Страница 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Страница 165: ...Troubleshooting ME LPMSZ SR 9...
Страница 186: ...Character Code Table ME LPMSZ SR 9...
Страница 199: ...Index ME LPMSZ SR 9...
Страница 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Страница 203: ...No 9000 0063 59V...
Страница 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...